uCT Computed Tomography X-ray System
System, X-Ray, Tomography, Computed. 510(k) K172135, from Shanghai United Imaging Healthcare Co., Ltd. (Shanghai, CN). Product code JAK, class 2.
As of Nov 19, 2026, K172135 is an FDA 510(k) held by Shanghai United Imaging Healthcare Co., Ltd., substantially equivalent on Mar 2, 2018 after 231 days, with 7 recalls tied to it in FDA's recall database.
- Review time: 231 days
- Recalls: 7
- Cited as a predicate by: 6 devices
uCT 760/780 is a computed tomography x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes and indicated for the whole body (including head, neck, cardiac and vascular).
- Philips Plus Computed Tomography SystemK033326 · Philips Medical Systems, Inc. · Oct 29, 2003
- uEXPLORERK231762 · Shanghai United Imaging Healthcare Co., Ltd. · Jan 18, 2024
- uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual Energy AnalysisK230162 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 1, 2023
- uCT ATLAS with uWS-CT-Dual Energy AnalysisK203448 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 11, 2021
- uCT 530, uCT 550K200016 · Shanghai United Imaging Healthcare Co., Ltd. · Feb 25, 2020
- Deep ReconK193073 · Shanghai United Imaging Healthcare Co., Ltd. · Jul 6, 2020
- uCT 530, uCT 550K181414 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 14, 2018
| Aug 11, 2026 | Z-3279-2026, Z-3280-2026Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images… | Open |
| Sep 12, 2025 | Z-0220-2026, Z-0219-2026Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement. | Open |
| Aug 5, 2020 | Z-0447-2021A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to… | Open |
| Jun 20, 2020 | Z-2703-2020The metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge. | Open |
| May 8, 2020 | Z-2522-2020Two issues were identified with the computed tomography x-ray system including an intermittent issue which may affect image data leading to artifacts; and intermittent scout scanning interruption due to occasional angle… | Terminated |
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 14, 2017
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files