Arca
Skip to content
Tools
Tools

uCT 530, uCT 550

System, X-Ray, Tomography, Computed. 510(k) K181414, from Shanghai United Imaging Healthcare Co., Ltd. (Shanghai, CN). Product code JAK, class 2.

As of Nov 21, 2026, K181414 is an FDA 510(k) held by Shanghai United Imaging Healthcare Co., Ltd., substantially equivalent on Aug 14, 2018 after 76 days, with 10 recalls tied to it in FDA's recall database.

  • Review time: 76 days
  • Recalls: 10
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The uCT Computed Tomography X-ray System uCT 530/550 is a computed tomography x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes and indicated for the whole body (including head, neck, vascular).

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate
  • uCT 530, uCT 550K200016 · Shanghai United Imaging Healthcare Co., Ltd. · Feb 25, 2020
  • uCT 520, uCT 528K183143 · Shangai United Imaging Healthcare Co., Ltd. · Jan 3, 2019

Recalls

Recalls FDA ties to K181414, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 11, 2026Z-3278-2026, Z-3277-2026Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images…Open
Sep 12, 2025Z-0217-2026, Z-0218-2026Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.Open
Aug 5, 2020Z-0445-2021, Z-0446-2021A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to…Open
Jun 20, 2020Z-2705-2020, Z-2704-2020The metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge.Open
May 23, 2020Z-2641-2020Two issues were identified with the computed tomography x-ray system including a service function which may cause false marking of a bad channel resulting in ring artifacts, and potential intermittent scout scanning…Open
May 8, 2020Z-2472-2020Two issues were identified with the computed tomography x-ray system including a service function which may cause false marking of a bad channel resulting in ring artifacts, and potential intermittent scout scanning…Open

Other JAK clearances

The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device

Record

Type
Traditional
Received
May 30, 2018
Review panel
Radiology
Regulation
21 CFR 892.1750

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.