ABL800 Flex With Flexq Module, Model ABL8XX
Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph. 510(k) K043218, from Radiometer Medical Aps (Bronshoj, DK). Product code CHL, class 2.
As of Nov 19, 2026, K043218 is an FDA 510(k) held by Radiometer Medical Aps, substantially equivalent on May 10, 2005 after 169 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 169 days
- Recalls: 3
- Cited as a predicate by: 4 devices
Indication for use information for the analytes measured by the ABL800 FLEX: pH: pH is the indispensable measure of acidemia or alkalemia and is therefore an essential part of the pH/blood gas measurement. The normal function of many metabolic processes requires a pH to be within a relatively narrow range. pO_{2 : The arterial oxygen tension is an indicator of the oxygen uptake in the lungs.
- ABL800 FlexK041874 · Radiometer Medical Aps · Oct 8, 2004
- Avl 9181 Electrolyte AnalyzerK972673 · Avl Scientific Corp. · Aug 20, 1997
- ABL80 FLEX and ABL80 FLEX CO-OXK151639 · Sendx Medical, Inc. · Dec 7, 2015
- ABL800 FLEX with AQURE connectivityK142898 · Radiometer Medical Aps · Jun 17, 2015
- Neonatal Bilirubin On Rapidlab Models 1245 and 1265K073537 · Siemens Medical Solutions Diagnostics · Jun 27, 2008
- ABL8X7 FlexK051968 · Radiometer Medical Aps · Oct 16, 2006
| Oct 8, 2012 | Z-2303-2013RADIOMETER became aware that some membranes may have enzyme residue on the outer membrane. The enzyme residue may cause an initial negative bias on the reported Lactate result upon replacement of the Lactate membrane. | Terminated |
| Apr 7, 2011 | Z-2571-2011Based on internal testing and user/customer complaint reports received, the firm determined that wrinkles may arise on the outer membrane of the calcium membrane units upon installation. Retention of fluids between the… | Terminated |
| Jan 16, 2007 | Z-0705-2007In some situations pre-registered patient data is not reset when leaving the pre-registration mode in the software. This occurs when a Safe Pico blood sampler associated with a specific patient is pre-registered in the… | Terminated |
- ABL90 FLEX PLUS System, safeCLINITUBESK252207 · Radiometer Medicals Aps · Apr 10, 2026
- i-STAT CG4+ cartridge with the i-STAT 1 SystemK244014 · Abbott Point of Care, Inc. · May 2, 2025
- ABL90 FLEX PLUS SystemK240998 · Radiometer Medicals Aps · Dec 13, 2024
- i-STAT CG8+ cartridge with the i-STAT 1 SystemK230285 · Abbott Point of Care, Inc. · Oct 27, 2023
- Stat Profile Prime Plus Analyzer SystemK221900 · Nova Biomedical Corporation · Sep 29, 2023
- i-STAT G3+ cartridge with the i-STAT 1 SystemK223857 · Abbott Point of Care, Inc. · Sep 15, 2023
- GEM Premier 7000 with IQM3K223608 · Instrumentation Laboratory Company · Aug 10, 2023
- EasyStat 300K211559 · Medica Corporation · Jan 27, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 22, 2004
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1120
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files