Luminos dRF Max, Luminos Agile Max, Uroskop Omnia Max, Multitom Rax

Interventional Fluoroscopic X-Ray System. 510(k) K173639, from Siemens Medi Cal Solutions, Inc. (Malvern, PA). Product code OWB, class 2.

As of Nov 18, 2026, K173639 is an FDA 510(k) held by Siemens Medi Cal Solutions, Inc., substantially equivalent on Apr 2, 2018 after 129 days, with 23 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Apr 2, 2018
  • Review time: 129 days
  • Recalls: 23
  • Cited as a predicate by: 3 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

Luminos Agile Max is a device intended to visualize anatomical structures by converting an X-ray pattern into a visible image. The system has medical applications ranging from gastrointestinal examinations to cranial, skeletal, thoracic and lung exposures as well as examinations of the urogenital tract.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF
  • Luminos AgileK111292 · Siemens Medical Solutions USA, Inc. · Jun 3, 2011
  • Axiom Luminos DrfK062623 · Siemens Medical Solutions USA, Inc. · Aug 22, 2007
  • Uroskop OmniaK101491 · Siemens Medical Solutions USA, Inc. · Jun 30, 2010
  • Multitom RaxK152928 · Siemens Medical Solutions USA, Inc. · Nov 13, 2015

Cited as a Predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K173639, newest first; each opens FDA's recall record
Dec 5, 2025Z-0999-2026A potential issue associated with LUMINOS Lotus Max and Luminos dRF Max systems with software version VF11 with bucky wall stand for mobile detectors and without ceiling stand .When switching quickly between organ…Open, Classified
Jun 4, 2025Z-1981-2025A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.Open, Classified
Jun 4, 2025Z-1982-2025A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.Open, Classified
Jul 2, 2024Z-2526-2024The support arm may unintentionally lower resulting in injury to persons when they are under the display ceiling/wall suspension when positioning the displaysOpen, Classified
Jul 2, 2024Z-2527-2024The support arm may unintentionally lower resulting in injury to persons when they are under the display ceiling/wall suspension when positioning the displaysOpen, Classified
Jul 2, 2024Z-2525-2024The support arm may unintentionally lower resulting in injury to persons when they are under the display ceiling/wall suspension when positioning the displaysOpen, Classified
Dec 21, 2022Z-1168-2023Potential risk of collision with the ceiling, wall, or objects which may result in serious injury to staff or patients due to room configuration parameters of the system being set to default valuesOpen, Classified
Dec 21, 2022Z-1165-2023Potential risk of collision with the ceiling, wall, or objects which may result in serious injury to staff or patients due to room configuration parameters of the system being set to default valuesOpen, Classified
Dec 21, 2022Z-1167-2023Potential risk of collision with the ceiling, wall, or objects which may result in serious injury to staff or patients due to room configuration parameters of the system being set to default valuesOpen, Classified
Dec 9, 2022Z-1002-2023There is potential for the footrest to detach from the patient table during use. Device intended to visualize anatomical structures by converting an Xray pattern into a visible image. The system has medical applications…Open, Classified
Nov 23, 2022Z-1479-2023Under certain unlikely circumstances during a fluoroscopic examination, the imaging system Fluorospot Compact might sporadically display an incorrect air kerma/air kerma rate related to the patient reference point,…Open, Classified
Nov 23, 2022Z-1481-2023Under certain unlikely circumstances during a fluoroscopic examination, the imaging system Fluorospot Compact might sporadically display an incorrect air kerma/air kerma rate related to the patient reference point,…Open, Classified
Nov 23, 2022Z-1480-2023Under certain unlikely circumstances during a fluoroscopic examination, the imaging system Fluorospot Compact might sporadically display an incorrect air kerma/air kerma rate related to the patient reference point,…Open, Classified
Sep 9, 2020Z-0806-2021After the March 2019 corrective action on the monitor support arm, there is a residual risk of the support arm becoming dislodged in cases when the monitor support arm is used intensely over a long period of time.Terminated
Jan 8, 2020Z-2756-2020Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control…Terminated
Jan 8, 2020Z-1333-2020Siemens became aware of an issue of incorrect use of the bypass key overriding the built-in collision control creating risk of collision with obstacles or persons when the operator uses the override function.Terminated
Jan 8, 2020Z-1331-2020Siemens became aware of an issue of incorrect use of the bypass key overriding the built-in collision control creating risk of collision with obstacles or persons when the operator uses the override function.Terminated
Jan 8, 2020Z-2755-2020Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control…Terminated
Jan 8, 2020Z-1337-2020A software bug may lead to one image to be assigned to two different patients, which could potentially affect medical diagnosis.Terminated
Jan 8, 2020Z-1338-2020A software bug may lead to one image to be assigned to two different patients, which could potentially affect medical diagnosis.Terminated
Jan 8, 2020Z-2757-2020Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control…Terminated
Jan 8, 2020Z-1332-2020Siemens became aware of an issue of incorrect use of the bypass key overriding the built-in collision control creating risk of collision with obstacles or persons when the operator uses the override function.Terminated
Feb 8, 2019Z-0985-2019The swivel arm holding the monitors may become dislodged from the carrying arm.Terminated

Other OWB Clearances

The newest 510(k)s for the same product code; their median review was 231 days; see every OWB device

Record

Type
Traditional
Received
Nov 24, 2017
Review panel
Radiology
Regulation
21 CFR 892.1650

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files