Uroskop Omnia

System, X-Ray, Fluoroscopic, Image-Intensified. 510(k) K101491, from Siemens Medical Solutions USA, Inc. (Mavern, PA). Product code JAA, class 2.

As of Nov 17, 2026, K101491 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Jun 30, 2010 after 29 days, with 12 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Jun 30, 2010
  • Review time: 29 days
  • Recalls: 12
  • Cited as a predicate by: 4 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The UROSKOP Omnia is a solid state detector fluoroscopic X-ray system, primarily for urological applications (functional x-ray diagnostics, endourology and minimal invasive urology/surgery). The system, which includes a radiologic/urologic treatment table, may be used for urological, gastroenterological and gynecological treatment, planning and diagnostic procedures including: - Querying and…

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF
  • U04K010942 · Siemens Medical Solutions USA, Inc. · Apr 12, 2001

Cited as a Predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K101491, newest first; each opens FDA's recall record
Jun 4, 2025Z-1981-2025A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.Open, Classified
Jun 4, 2025Z-1982-2025A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.Open, Classified
Sep 9, 2020Z-0805-2021After the March 2019 corrective action on the monitor support arm, there is a residual risk of the support arm becoming dislodged in cases when the monitor support arm is used intensely over a long period of time.Terminated
Feb 8, 2019Z-0984-2019The swivel arm holding the monitors may become dislodged from the carrying arm.Terminated
Apr 13, 2015Z-1670-2015Study and all acquired images deleted when using systems with software version VE10E. Acquisitions have to be repeated. Connection with portable detectors (MAX wi-D, MAX mini) is sporadic in image recovery. Pressing…Terminated
Sep 2, 2014Z-0004-2015Two malfunctions posing potential risk to patients were identified with Siemens Ysio Max, AXIOM Luminos dRF Max, Uroskop Omnia Max, and Luminos Agile Max systems with a specific set of serial numbers that will cause…Terminated
Jul 7, 2014Z-2292-2014It was discovered that during a RAD examination using Siemens Luminos dRF, Ysio or Uroskop Omnia systems with software version VB10C to VB10F and automatic exposure control, a highly unlikely malfunction can result in…Terminated
Sep 3, 2013Z-0374-2014A potential malfunction and hazard to patients exists when using the Ysio, Luminos Agile, Luminos dRF, and Uroskop Omnia systems with software version VC10, which may result in radiation continuing longer than required…Terminated
Sep 3, 2013Z-0140-2014When using systems operating with software versions VD10A/G during a RAD examination, a malfunction can result in radiation continuing longer than required resulting in an overexposed image that is not of diagnostic…Terminated
Aug 28, 2013Z-1845-2014When using systems operating with software versions VD10A/G during a RAD examination, a malfunction can result in the image appearing very dark, which may prompt unnecessary repetition of the examination.Terminated
May 6, 2013Z-0016-2014Siemens has discovered through product monitoring a potential malfunction when using system operating with software versions VB10D, VB10F, VB10C and VB10. During a RAD examination the possibility exists that radiation…Terminated
Feb 15, 2012Z-1159-2012Firm has become aware of unintended behavior when using Ysio, AXIOM dRF, AXIOM Luminos Agile/TF and Uroskop Omnia with RAD Fluoro Uro function using software version VC10A. Due to an error in the image pipeline, images…Terminated

Other JAA Clearances

The newest 510(k)s for the same product code; their median review was 110 days; see every JAA device

Record

Type
Special
Received
Jun 1, 2010
Review panel
Radiology
Regulation
21 CFR 892.1650

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files