Aestiva 7900, Aestiva MRI, Aestiva 7100, Aestiva 7100 Compact, Aespire 100, Aespire 7100, Aespire 7900, Aespire View, Avance, Avance CS2, Aisys, Aisys CS2

Gas-Machine, Anesthesia. 510(k) K172045, from Datex-Ohmeda, Inc. (Madison, WI). Product code BSZ, class 2.

As of Nov 19, 2026, K172045 is an FDA 510(k) held by Datex-Ohmeda, Inc., substantially equivalent on Nov 3, 2017 after 120 days, with 23 recalls tied to it in FDA's recall database.

  • Review time: 120 days
  • Recalls: 23

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Aespire Anesthesia Gas System with 7100 Ventilator is a gas machine that supplies set flows of medical gases to the breathing system. A large selection of frames, gases, and vaporizers give full control of the system configuration. It is available with up to three gases, two vaporizer positions and up to three cylinder connections. All models are available with O2/Air, O2/N2O, or O2/Air/N2O.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K172045, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jul 30, 2026Z-3190-2026, Z-3191-2026, Z-3192-2026, Z-3189-2026Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling…Open
Jul 12, 2024Z-0084-2025, Z-0075-2025, Z-0078-2025, Z-0082-2025, Z-0076-2025, Z-0077-2025, Z-0074-2025, Z-0080-2025, Z-0081-2025Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port.Open
Jun 1, 2022Z-1389-2022There is a potential reversal of the O2 and air cylinder pressure transducer connections.Terminated
May 27, 2022Z-1427-2022The base of the anesthesia system can have a crack and could potentially fracture resulting in a tip or overbalance of the anesthesia system. This can result in potential injury if it falls on a person.Open
Apr 25, 2022Z-1286-2022, Z-1285-2022Backup batteries can fail earlier than their estimated life.Open
Aug 2, 2021Z-2596-2021, Z-2595-2021The flow sensors built prior to June 2021 could have damaged tubes with small punctures or cuts that could cause leaks resulting in incorrect anesthesia machine tidal volumes potentially leading to over-delivery of…Open
Sep 17, 2020Z-0314-2021, Z-0312-2021, Z-0311-2021, Z-0313-2021Flow sensors could have damaged tubes in the form of small punctures or cuts.Open

Other BSZ clearances

The newest 510(k)s for the same product code; their median review was 265 days; see every BSZ device

Record

Type
Traditional
Received
Jul 6, 2017
Review panel
Anesthesiology
Regulation
21 CFR 868.5160

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files