Artis Q and Q.Zen- Modular Angiographic System
Interventional Fluoroscopic X-Ray System. 510(k) K123529, from Siemens Medical Solutions USA, Inc. (Mavern, PA). Product code OWB, class 2.
As of Nov 18, 2026, K123529 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Feb 26, 2013 after 102 days, with 25 recalls tied to it in FDA's recall database.
- Review time: 102 days
- Recalls: 25+
- Cited as a predicate by: 6 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFArtis is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that can be performed with the Artis family include cardiac angiography, neuroangiography, general angiography, rotational angiography, multipurpose angiography and whole body…
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Artis Zee / Zeegos With SW VC14K090745 · Siemens Medical Solutions USA, Inc. · Jun 18, 2009
Cited as a predicate
6 later 510(k) summaries name this device as a predicate- Artis zee/zeego & Artis Q/Q.zenK181407 · Siemens Medical Solution USA, Inc. · Aug 15, 2018
- Biograph mMR with mMR Angio Transfer OptionK172531 · Siemens Medical Solutions USA, Inc. · Nov 14, 2017
- ARTIS phenoK163286 · Siemens Medical Solution USA, Inc. · Mar 9, 2017
- Artis Zee/Zeego SW VC21K141574 · Siemens Medical Solutions USA, Inc. · Sep 5, 2014
- Artis OneK133580 · Siemens Medical Solutions USA, Inc. · Apr 28, 2014
- Sync-Rx SystemK132558 · Volcano Corporation · Dec 12, 2013
Recalls
Recalls FDA ties to K123529, newest first; the 25 newest; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Apr 9, 2019 | Z-1342-2019, Z-1341-2019In affected Artis systems the movement of the floating tabletop may be blocked after a collision sensor has been activated during system movement. | Terminated |
| Oct 19, 2018 | Z-0458-2019, Z-0459-2019Vibrations of the C-arm of the plane B may result in reduced image quality caused by the screw connection to the C-arm in the ceiling support | Terminated |
| Jul 29, 2018 | Z-3189-2018Temperature of the detector may fall out of its designed working range (cool down) due to incorrectly configured temperature control unit. This unintentional system behavior may occur while the unit is powered down for… | Terminated |
| Jun 22, 2018 | Z-2747-2018Potential hardware issue which may cause thermal effects and possible damage to system parts. | Terminated |
| May 1, 2018 | Z-2303-2018, Z-2304-2018, Z-2305-2018, Z-2306-2018, Z-2307-2018After the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure.… | Terminated |
| Sep 28, 2017 | Z-0709-2018The possibility exists for the wireless foot switch to fail due to impacts by external factors, such as electrostatic discharge that exceed a certain intensity. If the foot switch fails, it will no longer be able to be… | Terminated |
| Aug 24, 2017 | Z-0508-2018Within a specific number of Artis zee biplane and Artis Q biplane systems, a connection in the ceiling mount consisting of 12 screws may not have been attached and fastened according to quality standards. A quality… | Terminated |
| Jun 6, 2017 | Z-0706-2018Potential for liquid entry | Terminated |
| Feb 27, 2017 | Z-1466-2017A gap in the housing of the wireless foot switch could potentially result in liquids penetrating the interior. Such liquids may include disinfectants, cleaning agents and/ or bodily fluids. In rare cases, the… | Terminated |
| Feb 22, 2017 | Z-1534-2017In Artis systems with A100G generators, a component can be affected by aging which could result in the potential failure of a module in the high-voltage generator. | Terminated |
| Dec 8, 2016 | Z-0972-2017Siemens initiated a corrective action to address two possible, mutually independent causes of a system defect related to the following: - In Artis Systems with A100 Plus or A100G generators, an attempt to resume… | Terminated |
| Nov 1, 2016 | Z-0601-2017The possibility exists that the semi-automatic focus switch may not work as intended when pressing the footswitch multiple times. | Terminated |
| Jul 13, 2016 | Z-2395-2016The possibility exists for contaminants, in the form of biomass, to develop in the cooling system of Artis systems resulting in damage to the pump system. | Terminated |
| Jul 7, 2016 | Z-2344-2016Due to an error in the 19 Live Display, image reproduction may fail in the examination room and the potential exists for the loss of images immediately after system startup. | Terminated |
| Feb 18, 2016 | Z-3090-2017, Z-3089-2017, Z-3088-2017, Z-3091-2017Due to a leak in the cooling system, fluids could potentially seep into the equipment cabinet. Loss of coolant can results in a cooling system failure and subsequent system failure. This leek can occur sporadically in… | Terminated |
| Feb 18, 2016 | Z-1283-2016Due to a leak in the cooling system, fluids could potentially seep into the equipment cabinet. Loss of coolant can result in a cooling system failure and subsequent system failure. This leak can occur sporadically in… | Terminated |
Other OWB clearances
The newest 510(k)s for the same product code; their median review was 231 days; see every OWB device- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;EXTRON 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 16, 2012
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files