Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety Software and Supported Syringes (Pss)
Pump, Infusion. 510(k) K111386, from Smiths Medical MD, Inc. (St. Paul, MN). Product code FRN, class 2.
As of Nov 19, 2026, K111386 is an FDA 510(k) held by Smiths Medical MD, Inc., substantially equivalent on Aug 29, 2011 after 103 days, with 16 recalls tied to it in FDA's recall database.
- Review time: 103 days
- Recalls: 16
- Cited as a predicate by: 4 devices
"The Medfusion® Model 4000 Syringe Infusion Pump is indicated for the following uses: - In the administration of fluids requiring precisely controlled infusion rates including blood or blood products, lipids, drugs, antibiotics, Enteral solutions and other therapeutic fluids. - By the following delivery routes: arterial, epidural, intravenous, intrathecal, subcutaneous, and enteral.
- Medex 3000 Series Mr Syringe Infusion PumpK040899 · Medex, Inc. · Apr 30, 2004
- Pharmguard Toolbox, Model G6000782K042432 · Medex, Inc. · Jan 4, 2005
- Medley Syringe Pump Module System, Model 8110K023264 · Alaris Medical Systems, Inc. · Dec 19, 2002
- Medley System With Medication Management System (Mms)K030459 · Alaris Medical Systems, Inc. · Apr 4, 2003
- Novum IQ Syringe PumpK211125 · Baxter Healthcare Corporation · Aug 30, 2022
- Cobas Influenza A/B Nucleic Acid Test for Use on the Cobas Liat SystemK191729 · Roche Molecular Systems, Inc. · Jul 24, 2019
- t:slim Insulin Delivery System, t:flex Insulin Delivery System, Tandem Device UpdaterK160482 · Tandem Diabetes Care, Inc. · Jul 13, 2016
- Medfusion 4000 Pump Device Specific Reports Solfware for Pharmguard Server Version 2.0K141193 · Smiths Medical Asd, Inc. · Jul 25, 2014
| Dec 19, 2023 | Z-1541-2024, Z-1543-2024Medfusion Model 4000, 3500, and 3010 pumps manufactured or serviced with Barrel Clamp Guide (Part Number G6000716), Lot Numbers P0407365, P0486670, and P0561740 may contain a molding defect that could potentially lead… | Open |
| Dec 19, 2023 | Z-0864-2024Medfusion Model 4000 syringe infusion pumps, with the following software versions, may have the following issues: 1. Delivery During Motor Not Running High Priority Alarm (v1.0.0, v1.1.0, v1.1.1, v1.1.2), 2.… | Open |
| Aug 16, 2023 | Z-0079-2024A force sensor in the occlusion detector may drift out of calibration leading to increased occlusion detection times, false occlusion alarms, or a System Failure Alarm. If the force sensor calibration shift is large… | Open |
| Oct 10, 2022 | Z-0272-2023Potential for delay in sending Infusion Start Messages to third-party Electronic Health Record systems which may affect infusion auto-programming on the pump and documentation | Open |
| Apr 18, 2022 | Z-1271-2022Multiple issues with the potential for interruption of therapy or over-infusion: 1. Primary Audible Alarm (PAA), 2. Unanticipated Depleted Battery Alarms, 3. Time Base Alarm, 4. Intermittent Volume Over Time (IVOT) -… | Open |
| Jun 26, 2020 | Z-2734-2020, Z-2735-2020Inaccurate delivery can occur following an interrupted Bolus or Loading dose, if a specific sequence of events occurs. | Open |
| Oct 28, 2019 | Z-0610-2020There is an anomaly in Medfusion 4000 Syringe Pump Firmware version 1.7.0 that could potentially result in loss of primary audible and visual battery alarm functionality, and interruption of therapy. | Terminated |
| Oct 15, 2018 | Z-2554-2019Customers who utilize PharmGuard Server Software (PGS) with Medfusion 4000 pumps manufactured prior to November 10, 2017, may experience wireless network connectivity issues on certain pumps due to a potential Radio… | Terminated |
| Apr 13, 2018 | Z-2662-2018Certain Barrel Clamp Guides may contain a ridge that could potentially lead to spring slippage, resulting in the inability of the pump to recognize a loaded syringe or the pump, misidentifying the size of a loaded… | Terminated |
| Nov 13, 2017 | Z-1134-2018Certain Medfusion Syringe Pump Models, Series 3100, 3500, and 4000, may not recognize or may misidentify loaded medication syringes. The inability of a pump to recognize a syringe (i.e. the size of the syringe is… | Terminated |
| Aug 22, 2017 | Z-0313-2018Potential for the syringe barrel clamp mechanism to loosen, decreasing the pump's ability to accurately detect the diameter of the syringe barrel, resulting in the unit to initiate the "Invalid Syringe Size" alarm. | Terminated |
| Dec 3, 2015 | Z-0653-2022There have been intermittent issues with Supercap POST (power on self-test) and Backup Audible Alarm error codes outside of the pump warranty period. These alarms occur at start up when the pump goes through the… | Open |
| Nov 22, 2013 | Z-0540-2014Smiths Medical is conducting a recall involving all Medfusion 4000 Syringe Infusion Pumps. Smiths Medical has identified an issue with electrical shorting at the AC power receptacle. Shorting can occur when saline… | Terminated |
| Feb 14, 2012 | Z-2107-2012Smiths Medical has identified a software anomaly in the Medfusion 4000 Syringe Infusion Pump that causes a device history log corruption and triggers a Watchdog Fail-Safe alarm. When the device exhibits this failure… | Terminated |
- RemunityPRO+ Pump for Remodulin® (treprostinil) InjectionK253703 · Deka R&D Corp · Jul 24, 2026
- FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate TubingK252015 · Koru Medical Systems, Inc. · Jan 28, 2026
- Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)K251636 · Baxter Healthcare Corporation · Jul 28, 2025
- SIGMA Spectrum Infusion Pump with Master Drug LibraryK251640 · Baxter Healthcare Corporation · Jul 28, 2025
- MRidium 3870 MRI Infusion Pump System (3870)K242752 · Iradimed Corporation · May 28, 2025
- BD Alaris Infusion System with Guardrails Suite MXK243855 · Carefusion 303, Inc. · Apr 25, 2025
- Plum Solo™ Precision IV PumpK242114 · Icu Medical, Inc. · Apr 2, 2025
- Plum Duo™ Precision IV PumpK242115 · Icu Medical, Inc. · Apr 2, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 18, 2011
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files