Medex 3000 Series Mr Syringe Infusion Pump
Pump, Infusion. 510(k) K040899, from Medex, Inc. (Dublin, OH). Product code FRN, class 2.
As of Nov 20, 2026, K040899 is an FDA 510(k) held by Medex, Inc., substantially equivalent on Apr 30, 2004 after 24 days, with 21 recalls tied to it in FDA's recall database.
- Review time: 24 days
- Recalls: 21
- Cited as a predicate by: 3 devices
The Medex 3000 Series MRI Syringe Infusion Pump indications for use are as follows: - in the administration of fluids requiring precisely controlled infusion rates including blood or blood products, lipids, drugs, antibiotics, enteral solutions and other therapeutic fluids. - in the following delivery routes: arterial, epidural, intravenous, spinal, subcutaneous, and enteral.
- Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety Software and Supported Syringes (Pss)K111386 · Smiths Medical MD, Inc. · Aug 29, 2011
- Abc Syringe Infusion Pump, Model 4100K072603 · Elixir Corporation · Oct 23, 2008
- CompufloK053554 · Milestone Scientific, Inc. · Jul 10, 2006
| Dec 19, 2023 | Z-1540-2024, Z-1542-2024Medfusion Model 4000, 3500, and 3010 pumps manufactured or serviced with Barrel Clamp Guide (Part Number G6000716), Lot Numbers P0407365, P0486670, and P0561740 may contain a molding defect that could potentially lead… | Open |
| Dec 19, 2023 | Z-0863-2024Medfusion syringe pumps, with software versions before v6.0.0, may have the following issues:1. Delivery During Motor Not Running High Priority Alarm, 2. Infusion Restarted with Incorrect Parameters, 3. Screen Lock, 4.… | Open |
| Aug 16, 2023 | Z-0077-2024, Z-0076-2024, Z-0078-2024A force sensor in the occlusion detector may drift out of calibration leading to increased occlusion detection times, false occlusion alarms, or a System Failure Alarm. If the force sensor calibration shift is large… | Open |
| Apr 18, 2022 | Z-1272-2022Multiple issues with the potential for interruption of therapy or over-infusion: 1. Primary Audible Alarm (PAA), 2. Unanticipated Depleted Battery Alarms, 3. Time Base Alarm, 4. Intermittent Volume Over Time (IVOT) -… | Open |
| Jun 26, 2020 | Z-2734-2020, Z-2735-2020Inaccurate delivery can occur following an interrupted Bolus or Loading dose, if a specific sequence of events occurs. | Open |
| Apr 13, 2018 | Z-2662-2018Certain Barrel Clamp Guides may contain a ridge that could potentially lead to spring slippage, resulting in the inability of the pump to recognize a loaded syringe or the pump, misidentifying the size of a loaded… | Terminated |
| Nov 13, 2017 | Z-1136-2018, Z-1135-2018Certain Medfusion Syringe Pump Models, Series 3100, 3500, and 4000, may not recognize or may misidentify loaded medication syringes. The inability of a pump to recognize a syringe (i.e. the size of the syringe is… | Terminated |
| Aug 22, 2017 | Z-0314-2018Potential for the syringe barrel clamp mechanism to loosen, decreasing the pump's ability to accurately detect the diameter of the syringe barrel, resulting in the unit to initiate the "Invalid Syringe Size" alarm. | Terminated |
| Dec 3, 2015 | Z-0653-2022There have been intermittent issues with Supercap POST (power on self-test) and Backup Audible Alarm error codes outside of the pump warranty period. These alarms occur at start up when the pump goes through the… | Open |
| Jan 2, 2012 | Z-1206-2012Pumps rendered inoperable at power up (displaying a blank screen and alarm). | Terminated |
| Jun 22, 2010 | Z-2121-2010Smiths Medical is conducting a correction of Medfusion Syringe Infusion Pumps, Models 3010 and 3010a, with obsolete software versions 2.0.2, 2.0.3, and 2.0.4. Smiths Medical has found that pumps with obsolete software… | Terminated |
| May 14, 2010 | Z-0996-2013An issue with the plunger rod seal was identified where the seal had the potential to migrate inside the pump case top during slow rate/ high back pressure infusions. | Terminated |
| Nov 16, 2009 | Z-0651-2010, Z-0650-2010Smiths Medical has become aware of an increased trend in reports of Motor Not Running (MNR) and Motor Rate Error (MRE) alarm message events with certain Medfusion Syringe Infusion Pumps, Models 3010A and 3500 (Pump).… | Terminated |
| Dec 18, 2008 | Z-1018-2009, Z-1019-2009Delay in therapy. Keypad issues with Medfusion Syringe Infusion Pump, model numbers 3500-306 and 3500-415 ("Pump") have occurred during implementation or shortly after first being placed into use. These issues can be… | Terminated |
- RemunityPRO+ Pump for Remodulin® (treprostinil) InjectionK253703 · Deka R&D Corp · Jul 24, 2026
- FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate TubingK252015 · Koru Medical Systems, Inc. · Jan 28, 2026
- Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)K251636 · Baxter Healthcare Corporation · Jul 28, 2025
- SIGMA Spectrum Infusion Pump with Master Drug LibraryK251640 · Baxter Healthcare Corporation · Jul 28, 2025
- MRidium 3870 MRI Infusion Pump System (3870)K242752 · Iradimed Corporation · May 28, 2025
- BD Alaris Infusion System with Guardrails Suite MXK243855 · Carefusion 303, Inc. · Apr 25, 2025
- Plum Solo™ Precision IV PumpK242114 · Icu Medical, Inc. · Apr 2, 2025
- Plum Duo™ Precision IV PumpK242115 · Icu Medical, Inc. · Apr 2, 2025
- Type
- Traditional
- Received
- Apr 6, 2004
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files