Medley Syringe Pump Module System, Model 8110
Pump, Infusion. 510(k) K023264, from Alaris Medical Systems, Inc. (San Diego, CA). Product code FRN, class 2.
As of Nov 20, 2026, K023264 is an FDA 510(k) held by Alaris Medical Systems, Inc., substantially equivalent on Dec 19, 2002 after 80 days, with 7 recalls tied to it in FDA's recall database.
- Review time: 80 days
- Recalls: 7
- Cited as a predicate by: 3 devices
The MEDLEY™ Syringe Pump is intended for use in today’s growing professional healthcare environment for facilities that utilize syringe pumps for the delivery of fluids, medications, blood and blood products.
- Variable Pressure Syringe PumpK974332 · Alaris Medical Systems, Inc. · Dec 29, 1998
- Medex 3000 Series Syringe Infusion PumpK982640 · Medex, Inc. · Apr 6, 1999
- Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety Software and Supported Syringes (Pss)K111386 · Smiths Medical MD, Inc. · Aug 29, 2011
- CompufloK053554 · Milestone Scientific, Inc. · Jul 10, 2006
- Medley Pca Module, Model 8120K032233 · Alaris Medical Systems, Inc. · Sep 9, 2003
| Feb 11, 2026 | Z-1645-2026Due to product labeling not indicating which Transport Layer Security (TLS) version that must be enabled on hospital network to ensure secure Wi-Fi communication with Point-of-Care Units | Open |
| Nov 17, 2017 | Z-0322-2018The syringe plunger grippers may fail to automatically close around the syringe plunger press when the gripper control knob has been closed. | Terminated |
| Aug 8, 2016 | Z-2879-2016A software anomaly with the Alaris Syringe module software version 9.15 may cause an infusion to unexpectedly stop when the Syringe module is transitioning from one rate to another. | Terminated |
| Jul 21, 2015 | Z-2362-2015Channel Error code is displayed on the PC unit with an audio and visual alarm, and on the syringe module. After the error is cleared on the PCU, the syringe pump is unresponsive to key presses until the next power… | Terminated |
| Jun 12, 2009 | Z-1794-2009There is a potential risk of IUI connector failure in the Alaris System when these connectors become corroded or contaminated, which may result in an interruption of infusion with an audible and visual alarm. IUI… | Terminated |
| Mar 5, 2008 | Z-1712-2008A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failure of the U9 Socketed Integrated Circuits (U9 IC) on the… | Terminated |
| Mar 5, 2008 | Z-1711-2008A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors with the Alaris System due to the Inter-Unit Interface (IUI) connectors… | Terminated |
- RemunityPRO+ Pump for Remodulin® (treprostinil) InjectionK253703 · Deka R&D Corp · Jul 24, 2026
- FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate TubingK252015 · Koru Medical Systems, Inc. · Jan 28, 2026
- Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)K251636 · Baxter Healthcare Corporation · Jul 28, 2025
- SIGMA Spectrum Infusion Pump with Master Drug LibraryK251640 · Baxter Healthcare Corporation · Jul 28, 2025
- MRidium 3870 MRI Infusion Pump System (3870)K242752 · Iradimed Corporation · May 28, 2025
- BD Alaris Infusion System with Guardrails Suite MXK243855 · Carefusion 303, Inc. · Apr 25, 2025
- Plum Solo™ Precision IV PumpK242114 · Icu Medical, Inc. · Apr 2, 2025
- Plum Duo™ Precision IV PumpK242115 · Icu Medical, Inc. · Apr 2, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 30, 2002
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files