Medley Pca Module, Model 8120
Pump, Infusion, Pca. 510(k) K032233, from Alaris Medical Systems, Inc. (San Diego, CA). Product code MEA, class 2.
As of Nov 19, 2026, K032233 is an FDA 510(k) held by Alaris Medical Systems, Inc., substantially equivalent on Sep 9, 2003 after 50 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 50 days
- Recalls: 3
- Cited as a predicate by: 3 devices
The Medley PCA Module is intended for use in today's growing professional healthcare environment for facilities that utilize syringe pumps for the delivery of medications or fluids. The Medley PCA Module is indicated for use on adults, pediatrics, and neonates for continuous or intermittent delivery through clinically acceptable routes of administration; such as, intravenous (IV), subcutaneous…
- Medley Syringe Pump Module System, Model 8110K023264 · Alaris Medical Systems, Inc. · Dec 19, 2002
- Bard Pca Ii Pump With Program CartridgesK921994 · C.R. Bard, Inc. · Aug 3, 1992
- Perfusor Space Infusion Syringe Pump SystemK092313 · B.Braun Medical, Inc. · Nov 4, 2009
- Infusomat Space Volumetric Infusion Pump SystemK083689 · B.Braun Medical, Inc. · Jul 1, 2009
- Medley Pca Module, Model 8120K043299 · Alaris Medical Systems, Inc. · Dec 10, 2004
| Nov 17, 2017 | Z-0323-2018The syringe plunger grippers may fail to automatically close around the syringe plunger press when the gripper control knob has been closed. | Terminated |
| Jun 12, 2009 | Z-1794-2009There is a potential risk of IUI connector failure in the Alaris System when these connectors become corroded or contaminated, which may result in an interruption of infusion with an audible and visual alarm. IUI… | Terminated |
| Mar 4, 2009 | Z-1237-2009The Alaris PCA module can potentially infuse above or below the intended infusion dose. | Terminated |
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 21, 2003
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files