Medley Pca Module, Model 8120

Pump, Infusion, Pca. 510(k) K032233, from Alaris Medical Systems, Inc. (San Diego, CA). Product code MEA, class 2.

As of Nov 19, 2026, K032233 is an FDA 510(k) held by Alaris Medical Systems, Inc., substantially equivalent on Sep 9, 2003 after 50 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 50 days
  • Recalls: 3
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Medley PCA Module is intended for use in today's growing professional healthcare environment for facilities that utilize syringe pumps for the delivery of medications or fluids. The Medley PCA Module is indicated for use on adults, pediatrics, and neonates for continuous or intermittent delivery through clinically acceptable routes of administration; such as, intravenous (IV), subcutaneous…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K032233, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Nov 17, 2017Z-0323-2018The syringe plunger grippers may fail to automatically close around the syringe plunger press when the gripper control knob has been closed.Terminated
Jun 12, 2009Z-1794-2009There is a potential risk of IUI connector failure in the Alaris System when these connectors become corroded or contaminated, which may result in an interruption of infusion with an audible and visual alarm. IUI…Terminated
Mar 4, 2009Z-1237-2009The Alaris PCA module can potentially infuse above or below the intended infusion dose.Terminated

Record

Type
Traditional
Received
Jul 21, 2003
Review panel
General Hospital
Regulation
21 CFR 880.5725

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files