Arca
Skip to content
Tools
Tools

Medley Pca Module, Model 8120

Pump, Infusion, Pca. 510(k) K043299, from Alaris Medical Systems, Inc. (San Diego, CA). Product code MEA, class 2.

As of Nov 20, 2026, K043299 is an FDA 510(k) held by Alaris Medical Systems, Inc., substantially equivalent on Dec 10, 2004 after 10 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 10 days
  • Recalls: 3

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Medley PCA Module is intended for use in today's growing professional healthcare environment for facilities that utilize infusion devices for the delivery of medications or fluids. The Medley PCA Module is indicated for use on adults, pediatrics, and neonates for continuous or intermittent delivery through clinically acceptable routes of administration; such as intravenous (IV), subcutaneous…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K043299, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 4, 2020Z-2882-2020The Alaris PC unit can display incorrect syringe type and/or syringe sizes. This could result in delays in infusion, under-infusion, or over-infusion.Open
Mar 5, 2008Z-1712-2008A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failure of the U9 Socketed Integrated Circuits (U9 IC) on the…Terminated
Mar 5, 2008Z-1711-2008A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors with the Alaris System due to the Inter-Unit Interface (IUI) connectors…Terminated

Record

Type
Traditional
Received
Nov 30, 2004
Review panel
General Hospital
Regulation
21 CFR 880.5725

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.