Heartstart Mrx, Invasive Pressure & Temperature Options
Automated External Defibrillators (Non-Wearable). 510(k) K061707, from Philips Medical Systems (Andover, MA). Product code MKJ, class 3.
As of Nov 17, 2026, K061707 is an FDA 510(k) held by Philips Medical Systems, substantially equivalent on Aug 11, 2006 after 56 days, with 12 recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 11, 2006
- Review time: 56 days
- Recalls: 12
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFo be assigned Device Name: Philips Medical Systems, HeartStart MRx Defibrillator/Monitor The HeartStart MRx is for use for the termination of ventricular tachycardia and ventricular fibrillation. The device is for use by qualified medical personnel trained in the operation of the device and qualified by training in basic life support, advanced cardiac support, or defibrillation.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Heartstart Mrx, Model M3535AK031187 · Philips Medical Systems · Aug 27, 2003
- Heartstart Mrx With Q-Cpr Option, Models M3535A Or M3536AK051134 · Philips Medical Systems · Sep 8, 2005
- Zoll M Series Ibp Operation; Zoll M Series Temperature OptionK011865 · Zoll Medical Corp · Jul 31, 2001
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Hearstart Mrx With Airway Confimration AssistK130153 · Philips Medical Systems · Mar 12, 2013
- Heartstart Mrx, Models M3535A Or M3536AK063375 · Philips Medical Systems · Jan 11, 2007
Recalls
Recalls FDA ties to K061707, newest first; each opens FDA's recall record| Sep 28, 2017 | Z-0278-2018Philips MRx devices have an EtCO2 module that may contain contamination; this contamination (will/may) cause the device to be unable to display the EtCO2 or CO2 waveform (capnogram). | Terminated |
| Jul 17, 2017 | Z-0348-2018Issue with ECG out cables. When a Philips monitor/defibrillator is receiving an ECG signal from an auxiliary bedside monitor via a sync cable or ECG out cable, the following can occur if the monitor/defibrillator… | Terminated |
| Jul 12, 2017 | Z-0489-2018Affected units may have a defective component that is intended to protect the internal circuitry from high voltages during shock delivery. The defective component may also prevent delivery of shocks in AED mode. | Terminated |
| Feb 24, 2017 | Z-1417-2017HeartStart MRx Monitor/Defibrillator may may exhibit abnormal behavior when operating using a single battery as the sole source of power may fail to deliver therapy or monitoring | Terminated |
| Aug 26, 2016 | Z-2842-2016The handle can separate from the MRx housing due to breakage of mounts on the rear case. | Terminated |
| Apr 14, 2016 | Z-1612-2016MRx monitor/defibrillators could fail to charge because the therapy printed circuit board may have been loaded with an incorrect electronic component. | Terminated |
| Oct 14, 2015 | Z-0320-2016The following MRx software issue has been identified: MRx model M3535A with software version F.03.06 and earlier, and model M3536A with version T.00.05 and earlier may stop the automated Ready-For-Use (RFU) test in an… | Terminated |
| Dec 23, 2014 | Z-0219-2016MRx monitor/defibrillator could reboot at an indeterminate time, potentially causing therapy to be interrupted or delayed | Terminated |
| Nov 19, 2014 | Z-0262-2016MRx Defib can be susceptible to one or both issues: 1. The C02 Inlet Port associated with end-tidal carbon dioxide (EtCO2) monitoring on MRx Monitor/Defibrillators can be pushed into the MRx housing, making it… | Terminated |
| Nov 19, 2014 | Z-0273-2016When a Philips monitor/defibrillator is receiving an ECG signal from an auxiliary bedside monitor via a sync cable, the following can occur if the monitor/defibrillator experiences interference from electrical fast… | Terminated |
| Nov 19, 2014 | Z-0204-20161. Device will perform the weekly automated tests hourly, which could cause the therapy capacitors to degrade sooner than intended and 2. While connected to AC or DC power and with no battery installed or the battery… | Terminated |
| Nov 19, 2014 | Z-0963-2015Device may malfunction, which could cause therapy to be delayed, disabled, or delivered inadvertently. | Terminated |
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Jun 16, 2006
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5310
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files