Extracorporeal Blood Pumping Syst for Hemofiltrat
Accessories, Blood Circuit, Hemodialysis. 510(k) K911315, from Baxter Healthcare Corp (Round Lake, IL). Product code KOC, class 2.
As of Nov 20, 2026, K911315 is an FDA 510(k) held by Baxter Healthcare Corp, substantially equivalent on Oct 30, 1991 after 218 days, with 1 recall tied to it in FDA's recall database.
- Review time: 218 days
- Recalls: 1
- Cited as a predicate by: 3 devices
- Blood Monitor PumpK970591 · Baxter Healthcare Corp · Sep 9, 1997
- Edwards Aqualine Sterile Tubing Set; Edwards Aqualins Sterile Tubing Set; Edwards Aquaspike and AquasafeK063293 · Edwards Lifesciences Services GmbH · Mar 23, 2007
- Baxter Accura System, Model 5M5660K021615 · Baxter Healthcare Corp · Nov 18, 2002
| Started | Recall | Status |
|---|---|---|
| Dec 21, 2005 | Z-0681-06Advisory to alert users to assure that the hemofilter of the blood line is in the horizontal position to avoid kinking of the bloodline tubing to avoid hemolysis, and to show the compatible blood tubing sets to be used… | Terminated |
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series (AL-ADC-E(U),…K242176 · Nikkiso Co., Ltd. · May 15, 2025
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series AL-ADC-PU,…K242479 · Nikkiso Co., Ltd. · May 15, 2025
- Blood Tubing Lines for Hemodialysis AV06C-EK231589 · Nikkiso Co., Ltd. · Jul 28, 2023
- Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for Hemodialysis C18 SeriesK230514 · Nikkiso Co., Ltd. · Jun 16, 2023
- Type
- Traditional
- Received
- Mar 26, 1991
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5820
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files