Blood Tubing Lines for Hemodialysis AV06C-E
Accessories, Blood Circuit, Hemodialysis. 510(k) K231589, from Nikkiso Co., Ltd. (Shibuya-Ku, JP). Product code KOC, class 2.
As of Nov 17, 2026, K231589 is an FDA 510(k) held by Nikkiso Co., Ltd., substantially equivalent on Jul 28, 2023 after 57 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 28, 2023
- Review time: 57 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThis device is indicated for hemodialysis prescribed by physicians for adult patients with acute and chronic renal failure, treated in hospitals and dialysis clinics by qualified operators. This device is not indicated for pediatric patients. It is not for home use. This device is made up of disposable bloodlines intended to provide extracorporeal access to a patient’s blood during hemodialysis.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Nikkline Blood Tubing Lines With Transducer Protectors, Models AV06A-P, AVO6B-P, AV06C-PK082719 · Nikkiso Co., Ltd. · Mar 30, 2009
Other KOC Clearances
The newest 510(k)s for the same product code; their median review was 267 days; see every KOC device- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR…K242176 · Nikkiso Co., Ltd. · May 15, 2025
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR…K242479 · Nikkiso Co., Ltd. · May 15, 2025
- Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for…K230514 · Nikkiso Co., Ltd. · Jun 16, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 1, 2023
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5820
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files