da Vinci SP Surgical System, EndoWrist SP Instruments, and Accessories
System, Surgical, Computer Controlled Instrument. 510(k) K182371, from Intuitive Surgical, Inc. (Sunnyvale, CA). Product code NAY, class 2.
As of Nov 18, 2026, K182371 is an FDA 510(k) held by Intuitive Surgical, Inc., substantially equivalent on Mar 14, 2019 after 195 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 195 days
- Recalls: 4
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFda Vinci SP® Surgical System, Model SP1098 The Intuitive Surgical ® Endoscopic Instrument Control System ( da Vinci SP® Surgical System, Model SP1098) is intended to assist in the accurate control of Intuitive Surgical EndoWrist SP® Instruments during urologic surgical procedures that are appropriate for a single port approach and transoral otolaryngology surgical procedures in the oropharynx…
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- da Vinci SP Surgical System, EndoWrist SP Instruments, and AccessoriesK173906 · Intuitive Surgical, Inc. · May 31, 2018
- Intuitive Surgical Endoscopic Instrument Control Systems, Models IS1200, IS2000 and IS3000K090993 · Intuitive Surgical, Inc. · Dec 16, 2009
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- da Vinci SP Surgical System, Model SP1098, EndoWrist SP Instruments, and AccessoriesK202571 · Intuitive Surgical, Inc. · Nov 12, 2020
- da Vinci SP Surgical SystemK192717 · Intuitive Surgical, Inc. · Sep 28, 2020
Recalls
Recalls FDA ties to K182371, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Apr 22, 2026 | Z-2521-2026Operative components of surgical systems potentially distributed with E-brake retainer pin, so in event of a structural column failure, the E-brake pin would prevent E-brake engagement and may result in uncontrolled… | Open |
| May 12, 2025 | Z-2722-2026Robotic-assisted surgical system arm drapes may detach from the instrument arm due to an issue involving the drape rings located at the top of the product, which may expose a section of instrument arm, which may result… | Open |
| Mar 13, 2024 | Z-1518-2024Surgical system may have inadequately welded top and/or bottom belts in the link 2 of the entry guide manipulator assembly/instrument arm joints, that may cause the following, 1) Top Failure: internal tissue injuries,… | Open |
| Sep 22, 2021 | Z-0419-2022Issue was identified during internal engineering evaluation. Use of the system with the affected software version may experience either an inability to deliver energy or an inadvertent delivery of energy. Use may… | Open |
Other NAY clearances
The newest 510(k)s for the same product code; their median review was 89 days; see every NAY device- da Vinci Xi Surgical System (IS4000);da Vinci X Surgical System (IS4200)K263592 · Intuitive Surgical, Inc. · Oct 30, 2026
- da Vinci Surgical System, Model IS5000K261823 · Intuitive Surgical, Inc. · Sep 8, 2026
- da Vinci Surgical System, Model IS5000K261824 · Intuitive Surgical, Inc. · Jul 31, 2026
- da Vinci Firefly Imaging SystemK260695 · Intuitive Surgical · May 22, 2026
- Senhance Ultrasonic SystemK254192 · Asensus Surgical · May 12, 2026
- da Vinci Force Feedback InstrumentsK253986 · Intuitive Surgical, Inc. · Mar 11, 2026
- da Vinci Surgical System (IS5000)K251739 · Intuitive Surgical, Inc. · Jan 16, 2026
- da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorK253556 · Intuitive Surgical, Inc. · Jan 16, 2026
Elsewhere
- Japan approved da Vinci X Surgical System, the same brandPMDA · Jun 26, 2019
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 31, 2018
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files