NOxBOXi Nitric Oxide Delivery System

Apparatus, Nitric Oxide Delivery. 510(k) K171696, from Praxair Distribution, Inc. (Danbury, CT). Product code MRN, class 2.

As of Nov 20, 2026, K171696 is an FDA 510(k) held by Praxair Distribution, Inc., substantially equivalent on Oct 2, 2018 after 482 days, with 6 recalls tied to it in FDA's recall database.

  • Review time: 482 days
  • Recalls: 6
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The NOxBOXi Nitric Oxide Delivery System is intended for use by healthcare professionals for the delivery and monitoring of a constant (user set) concentration of nitric oxide (NO) and the monitoring of NO2 and O2 in the inspiratory ventilator lines of a patient undergoing nitric oxide therapy (iNO).

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K171696, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 14, 2026Z-3306-2026Potential for irregular oxygen readings due to a manufacturing issue affecting certain oxygen sensors.Open
Aug 19, 2026Z-3165-2026Potential for oxygen tubing leaks due to failure of the tubing or tubing connection, which may lead to oxygen desaturation.Open
Sep 9, 2025Z-0029-2026The unexpected internal fault / system diagnostic error to result when a rapid succession of button selections is made to the user interface without waiting for the device to respond to user prompts.Open
Sep 9, 2025Z-0028-2026Fluctuations may be more likely to occur if the total flow through the device sensor (used by the device to determine flow) is less than the minimum device requirement of 0.5 LPM. In addition, dose fluctuations have…Open
Jul 19, 2023Z-2544-2025Replacement of the internal Sample Pump due to high failure rates.Open
May 3, 2023Z-1667-2023Device may experience malfunctions due to misalignment of the check valve in the manifold. If the device fails, there is a risk of nitric oxide leak, oxygen gas leak, or earlier cylinder gas changeover than expected or…Terminated

Other MRN clearances

The newest 510(k)s for the same product code; their median review was 238 days; see every MRN device

Record

Type
Traditional
Received
Jun 7, 2017
Review panel
Anesthesiology
Regulation
21 CFR 868.5165

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files