Monitor B125, Monitor B105
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). 510(k) K171580, from Ge Medical Systems (China) Co., Ltd. (Wuxi, CN). Product code MHX, class 2.
As of Nov 17, 2026, K171580 is an FDA 510(k) held by Ge Medical Systems (China) Co., Ltd., substantially equivalent on Nov 1, 2017 after 154 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Nov 1, 2017
- Review time: 154 days
- Recalls: 1
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Monitor B125/B105 is a portable multi-parameter unit to be used for monitoring, recording, and to generate alarms for multiple physiological parameters of adult, pediatric, and neonatal patients in a hospital environment and during intra-hospital transport. The Monitor B125/B105 is intended for use under the direct supervision of a licensed health care practitioner.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Monitor B40K151063 · Ge Medical Systems China Co., Ltd. · Dec 15, 2015
- Carescape Monitor B650K102239 · GE Healthcare Finland Oy · Oct 18, 2010
- Datex-Ohmeda S/5 Single-Width Airway Module, E-Minic And AccessoriesK052582 · GE Healthcare · Oct 14, 2005
- CARESCAPE Central Station V2K162012 · GE Healthcare · Sep 15, 2016
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Monitor B125, Monitor B105K201941 · Ge Medical Systems Information Technologies, Inc. · Nov 4, 2020
Recalls
Recalls FDA ties to K171580, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Sep 11, 2018 | Z-0587-2019Patient monitors may restart due to network overload caused by network configuration. | Open, Classified |
Other MHX Clearances
The newest 510(k)s for the same product code; their median review was 226 days; see every MHX device- Radius VSM and AccessoriesK260676 · Masimo Corporation · Oct 14, 2026
- Carescape ONE; Carescape Dock F0; TruSignal ECG MM; TruSignal PRES MM; TruSignal TEMP MM; TruSignal SpO2 MM 1.8M;…K260656 · GE Healthcare Finland Oy · Sep 1, 2026
- Carescape Canvas 1000; Carescape Canvas Smart DisplayK260343 · GE Healthcare Finland Oy · Aug 28, 2026
- Infinity® Acute Care System (IACS) VG8.1K260579 · Draeger Medical Systems, Inc. · Aug 20, 2026
- Telemetry Monitor (iT30, iT50)K251508 · Edan Instruments, Inc. · Aug 6, 2026
- Monitor B105M; Monitor B125M; Monitor B155M; Monitor B105P; Monitor B125PK253277 · Ge Medical Systems Information Technologies, Inc. · Jul 24, 2026
- Radius VSM and AccessoriesK254209 · Masimo Corporation · Jun 4, 2026
- M12 Telemetry SystemK252840 · Global Instrumentation, LLC · May 29, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 31, 2017
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files