Carescape Monitor B650
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). 510(k) K102239, from GE Healthcare Finland Oy (Helsinki, FI). Product code MHX, class 2.
As of Nov 17, 2026, K102239 is an FDA 510(k) held by GE Healthcare Finland Oy, substantially equivalent on Oct 18, 2010 after 70 days, with 8 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 18, 2010
- Review time: 70 days
- Recalls: 8
- Cited as a predicate by: 6 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe CARESCAPE Monitor B650 is a multi-parameter patient monitor intended for use in multiple areas and intrahospital transport within a professional healthcare facility. The CARESCAPE Monitor B650 is intended for use on adult, pediatric, and neonatal patients and on one patient at a time.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Carescape Monitor B850K092027 · Ge Medical Systems Information Technologies · Aug 28, 2009
- Datex-Ohmeda S/5 Compact Anesthesia Monitor With L-CANE05A And L-CANE05A SoftwareK061185 · GE Healthcare · May 15, 2006
- Ek-Pro Arrhythmia Detection AlgorithmK031320 · Ge Medical Systems Information Technologies · May 6, 2003
- Datex-Ohmeda S/5 Anesthesia Monitor With L-ANEO7 And L-ANEO7A Software Using F-CU8 Or…K092680 · GE Healthcare Finland Oy · Sep 23, 2009
Cited as a Predicate
6 later 510(k) summaries name this device as a predicate- Monitor B125, Monitor B105K171580 · Ge Medical Systems (China) Co., Ltd. · Nov 1, 2017
- Monitor B40K151063 · Ge Medical Systems China Co., Ltd. · Dec 15, 2015
- Carescape Monitor B450K132533 · GE Healthcare Finland Oy · Dec 4, 2013
- Carescape Monitor B650K131223 · GE Healthcare Finland Oy · Aug 28, 2013
- Monitor B40K130584 · Ge Medical Systems China Co., Ltd. · Jun 26, 2013
- Procare Monitor B40K120598 · Ge Medical Systems China Co., Ltd. · Jul 19, 2012
Recalls
Recalls FDA ties to K102239, newest first; each opens FDA's recall record| May 25, 2018 | Z-2340-2018When multiple CARESCAPE Monitor B650 units are connected to the same network and a network overload occurs for a prolonged time, the monitors may simultaneously restart as designed. The monitor restart will not be… | Open, Classified |
| May 4, 2015 | Z-1606-2015The heart rate could be calculated from pacer pulses without indication that pacemaker detection is OFF in some combinations of Bx50 monitors, a PDM, and CIC/CSCS. Then the monitor does not show the Pacer Off message… | Terminated |
| Jul 7, 2014 | Z-2114-2014Possible sound loss associated with the CARESCAPE Monitor B650. When an external display is connected to the CARESCAPE Monitor B650 using a USB extender cable with an active USB hub, the system may experience a sound… | Terminated |
| Feb 28, 2014 | Z-1175-2014GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. These issues include both NIBP (Non-Invasive Blood Pressure) and Bed to Bed… | Terminated |
| Dec 27, 2013 | Z-0854-2014GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. These included 25 issues related to NIBP (Non-InvasiVentilation Alarms:ve Blood… | Terminated |
| Jul 12, 2012 | Z-2256-2013GE Healthcare has recently become aware of a number of potential issues associated with the CARESCAPE Monitor B650. No injuries or illnesses have been reported. | Terminated |
| Sep 30, 2011 | Z-0823-2013GE Healthcare has become aware of potential issues associated with the CARESCAPE Monitor B650. There have been no reported illnesses or injuries that have occurred with the use of the device. | Terminated |
| Mar 23, 2011 | Z-1930-2011GE Healthcare has become aware of a potential safety issue associated with the CARESCAPE Monitor B650 & B850 Cardiac Output measurement using Patient Data Module (PDM), and activation of ECG Leads Off alarm in specific… | Terminated |
Other MHX Clearances
The newest 510(k)s for the same product code; their median review was 226 days; see every MHX device- Radius VSM and AccessoriesK260676 · Masimo Corporation · Oct 14, 2026
- Carescape ONE; Carescape Dock F0; TruSignal ECG MM; TruSignal PRES MM; TruSignal TEMP MM;…K260656 · GE Healthcare Finland Oy · Sep 1, 2026
- Carescape Canvas 1000; Carescape Canvas Smart DisplayK260343 · GE Healthcare Finland Oy · Aug 28, 2026
- Infinity® Acute Care System (IACS) VG8.1K260579 · Draeger Medical Systems, Inc. · Aug 20, 2026
- Telemetry Monitor (iT30, iT50)K251508 · Edan Instruments, Inc. · Aug 6, 2026
- Monitor B105M; Monitor B125M; Monitor B155M; Monitor B105P; Monitor B125PK253277 · Ge Medical Systems Information Technologies, Inc. · Jul 24, 2026
- Radius VSM and AccessoriesK254209 · Masimo Corporation · Jun 4, 2026
- M12 Telemetry SystemK252840 · Global Instrumentation, LLC · May 29, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 9, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files