Quadrox-I, Quadrox-Id, Quadrox-Ir Oxygenators
Oxygenator, Cardiopulmonary Bypass. 510(k) K132829, from Maquet Cardiopulmonary, AG (Wayne, NJ). Product code DTZ, class 2.
As of Nov 20, 2026, K132829 is an FDA 510(k) held by Maquet Cardiopulmonary, AG, substantially equivalent on Oct 8, 2013 after 29 days, with 1 recall tied to it in FDA's recall database.
- Review time: 29 days
- Recalls: 1
- Cited as a predicate by: 2 devices
The membrane oxygenator Quadrox-i Adult is intended for the use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. Within the specified flow rate range, the device oxygenates the blood, eliminates carbon dioxide and regulates blood temperature.
- Quadrox-I Adult With and Without Integrated Arterial Filter With Softline Coating, Model# Hmo 70000, Hmo 71000K082117 · Maquet Cardiopulmonary, AG · Feb 18, 2009
- Quadrox-I Adult Microporous Membrane Oxygenator With Bioline Coating, Model Behmo70000,BEQ-HMO70000K090511 · Maquet Cardiopulmonary, AG · Jun 12, 2009
- Quadrox-I Small Adult With and Without Intergrated Arterial Filter With Softline Coating, Models Hmo 50000, Hmo 51000K090689 · Maquet Cardiopulmonary, AG · Oct 29, 2009
- Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline Coating and W/ Integrated Arterial Filter W/ Bioline CK093522 · Maquet Cardiopulmonary, AG · Dec 7, 2009
- Quadrox-I Pediatric Microporous Membrane Oxygenator With Integrated Arterial Filter With Softline / Bioline CoatingK103191 · Maquet Cardiopulmonary, AG · Mar 8, 2011
- Quadrox-I Neonatal Microporous Membrane Oxygenator With Integrated Arterial Filter With Softline/Bioline CoatingK102464 · Maquet Cardiopulmonary, AG · Mar 4, 2011
- Quadrox-Id Adult Diffusion Membrane Oxygenator With Softline Coating, Model: Be-Hmod 70000-USA, Beq-Hmod 70000-USA, HmodK101153 · Maquet Cardiopulmonary, AG · Dec 8, 2010
- QUADROX-i Adult/Small Adult Oxygenators;QUADROX-iD Adult OxygenatorsK150267 · Maquet Cardiopulmonary, AG · May 7, 2015
- Quadrox-Ir Adult and Small AdultK133265 · Maquet Cardiopulmonary, AG · Nov 12, 2013
| Started | Recall | Status |
|---|---|---|
| Mar 5, 2015 | Z-1689-2015A potential issue was detected that could result in blood leakage from the gas outlet port in all lots of Quadrox-iD Adult Diffusion Membrane Oxygenator with Bioline and Softline Coatings, Custom Tubing Packs and… | Terminated |
- HORIZON 8AF (Integrated OXY MODULE 8AF and Horizon CVR) (US5305)K261438 · Eurosets S.R.L · Sep 14, 2026
- Lifemotion Disposable Membrane OxygenatorK253838 · Lifemotion Medical Technology Co., Ltd. · Mar 16, 2026
- Quantum Perfusion Blood Oxygenator ECC VT160-E3 (VT160-E3); Quantum Perfusion Blood Oxygenator ECC VT200-E3 (VT200-E3);…K240934 · Spectrum Medical S.R.L. · Mar 12, 2026
- Horizon AF Plus System (Integrated A.L. One AF Plus OXYGENATOR and Horizon CVR) (US5300); A.L. One AF Plus OXYGENATOR…K250821 · Eurosets S.R.L · Dec 12, 2025
- Trilly Pediatric Oxygenator with Integrated Arterial Filter (US5232)K242503 · Eurosets S.R.L · Nov 24, 2025
- Quantum Perfusion Blood Oxygenator VT75-E1, Quantum Perfusion Blood Oxygenator VT75-E2K231982 · Qura S.R.L · Sep 12, 2024
- Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator…K240666 · Medtronic Perfusion Systems · Jul 10, 2024
- Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541); Affinity NT Oxygenator with Balance Biosurface…K241352 · Medtronic, Inc. · Jun 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Sep 9, 2013
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4350
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files