Arca
Skip to content
Tools
Tools

Quadrox-I Pediatric Microporous Membrane Oxygenator With Integrated Arterial Filter With Softline / Bioline Coating

Oxygenator, Cardiopulmonary Bypass. 510(k) K103191, from Maquet Cardiopulmonary, AG (Hirrlingen, DE). Product code DTZ, class 2.

As of Nov 19, 2026, K103191 is an FDA 510(k) held by Maquet Cardiopulmonary, AG, substantially equivalent on Mar 8, 2011 after 131 days, with 4 recalls tied to it in FDA's recall database.

  • Review time: 131 days
  • Recalls: 4
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The membrane oxygenator QUADROX-i Pediatric is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. It is designed for a blood flow rate of 0.2 – 2.8 l/min and is intended for the treatment of pediatric patients. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide and regulates the blood temperature.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K103191, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
May 18, 2023Z-1655-2023Product packaging may exhibit small pinholes which may not be visible to the unaided eye, compromising the sterile barrier of the packaging. Exposure to non-sterile device may result in inflammation, infection, sepsis,…Open
May 18, 2023Z-1641-20231. An accessory may be improperly placed during packaging, causing creases and damage to the accessory's sterile pouch. 2. Product packaging may exhibit holes, cracks, dents, and crushed areas. Both issues may…Open
Aug 15, 2013Z-2262-2013The manufacturer has conducted a review of the results of product testing performed during the last twelve months and has identified specific lots of product which may not meet specifications for bond strength on the…Terminated
Jun 12, 2012Z-0160-2013It has come to firm's attention that, in some rare cases, the blood outlet connector on some models of MAQUET Oxygenators may detach from the oxygenator. This event has occurred in about 0.01% (1:10,000) of units…Terminated

Other DTZ clearances

The newest 510(k)s for the same product code; their median review was 269 days; see every DTZ device

Record

Type
Traditional
Received
Oct 28, 2010
Review panel
Cardiovascular
Regulation
21 CFR 870.4350

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.