Integra Licox PTO2 Monitor

Device, Monitoring, Intracranial Pressure. 510(k) K131184, from Integra Lifesciences Corp. (Burlington, MA). Product code GWM, class 2.

As of Nov 21, 2026, K131184 is an FDA 510(k) held by Integra Lifesciences Corp., substantially equivalent on Aug 30, 2013 after 127 days, with 5 recalls tied to it in FDA's recall database.

  • Review time: 127 days
  • Recalls: 5

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Integra Licox PtO₂ Monitor measures oxygen partial pressure (PtO₂) and temperature in brain tissue and these parameters are used together as an aid in the determination of the perfusion status of cerebral tissue local to sensor placement. Monitor values are relative within an individual, and should not be used as the sole basis for determining a diagnosis or therapy.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K131184, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 14, 2015Z-1618-2015Integra LifeSciences Corporation is recalling Integra's Camino ICP Monitor (CAM02) & Licox PtO2 Monitor ( LCX02 & LCX02R) due to complaints that the audible speaker malfunctions.Terminated
Apr 14, 2015Z-1620-2015, Z-1619-2015Integra LifeSciences Corporation is recalling Integra's Camino ICP Monitor (CAM 02) & Licox PtO2 Monitor ( LCX02 & LCX02R) due to complaints that the audible speaker malfunctions.Terminated
Aug 18, 2014Z-0201-2015Integra LifeSciences Corporation received 2 complaints that the USB port on the Licox Pt02 monitor does not consistently provide the user the ability to extract the Pt02 trend data according to the User's Manual for the…Terminated
Apr 16, 2014Z-1675-2014Integra LifeSciences has identified through a small number of complaints that some lot numbers of Licox Test Kits (Catalog Number BC10R) may provide erroneous "calibration test failure" message when they are used with…Terminated

Other GWM clearances

The newest 510(k)s for the same product code; their median review was 210 days; see every GWM device

Record

Type
Traditional
Received
Apr 25, 2013
Review panel
Neurology
Regulation
21 CFR 882.1620

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files