Arca
Skip to content
Tools
Tools

CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)

Device, Monitoring, Intracranial Pressure. 510(k) K232890, from Integra Lifesciences Production Corporation (Mansfield, MA). Product code GWM, class 2.

As of Nov 20, 2026, K232890 is an FDA 510(k) held by Integra Lifesciences Production Corporation, substantially equivalent on Feb 4, 2024 after 139 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 139 days
  • Recalls: 1

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The ICP Monitor is intended for use as an interface between compatible strain gauge type pressure transducers and standard physiological pressure monitoring systems. The ICP Monitor is also intended for use as an independent pressure monitor for displaying the mean, systolic and diastolic values of a physiologic pressure waveform in the absence of an external patient monitor.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K232890, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Oct 5, 2023Z-0548-2024Firm is expanding the existing recall RES 90457 for the Cerelink, initiated in June 2022, to include all CereLink ICP Extension Cables. The updated corrective action includes a design change to the extension cable to…Open

Other GWM clearances

The newest 510(k)s for the same product code; their median review was 210 days; see every GWM device

Record

Type
Traditional
Received
Sep 18, 2023
Review panel
Neurology
Regulation
21 CFR 882.1620

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.