CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)
Device, Monitoring, Intracranial Pressure. 510(k) K232890, from Integra Lifesciences Production Corporation (Mansfield, MA). Product code GWM, class 2.
As of Nov 20, 2026, K232890 is an FDA 510(k) held by Integra Lifesciences Production Corporation, substantially equivalent on Feb 4, 2024 after 139 days, with 1 recall tied to it in FDA's recall database.
- Review time: 139 days
- Recalls: 1
The ICP Monitor is intended for use as an interface between compatible strain gauge type pressure transducers and standard physiological pressure monitoring systems. The ICP Monitor is also intended for use as an independent pressure monitor for displaying the mean, systolic and diastolic values of a physiologic pressure waveform in the absence of an external patient monitor.
- CereLink ICP MonitorK210993 · Integra Lifesciences Production Corporation · Apr 30, 2021
| Started | Recall | Status |
|---|---|---|
| Oct 5, 2023 | Z-0548-2024Firm is expanding the existing recall RES 90457 for the Cerelink, initiated in June 2022, to include all CereLink ICP Extension Cables. The updated corrective action includes a design change to the extension cable to… | Open |
- Pressio 3 Multi-parameter Neuromonitoring SystemK252241 · Sophysa · Apr 10, 2026
- Neurovent-P (092946-003); Neurovent (092956-003); Neurovent-Ifd-R (095317-003); Neurovent-Ifd-S (091678-003);…K250285 · Raumedic AG · Aug 29, 2025
- B4C System - Addition of new sensor model (BcSs-PICNIW-2000)K240821 · Braincare Desenvolvimento E Inovação Tecnológica S.A. · Jul 18, 2024
- B4C SystemK201989 · Braincare Desenvolvimento E Inovacao Tecnologica S.A. · Oct 8, 2021
- CereLink ICP MonitorK210993 · Integra Lifesciences Production Corporation · Apr 30, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 18, 2023
- Review panel
- Neurology
- Regulation
- 21 CFR 882.1620
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files