CereLink ICP Monitor

Device, Monitoring, Intracranial Pressure. 510(k) K210993, from Integra Lifesciences Production Corporation (Mansfield, MA). Product code GWM, class 2.

As of Nov 19, 2026, K210993 is an FDA 510(k) held by Integra Lifesciences Production Corporation, substantially equivalent on Apr 30, 2021 after 28 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 28 days
  • Recalls: 2
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The ICP Monitor is intended for use as an interface between compatible strain-gauge type pressure transducers and standard physiological pressure monitoring systems. The ICP Monitor is also intended for use as an independent pressure monitor for displaying the mean, systolic and diastolic values of a physiologic pressure waveform in the absence of an external patient monitor.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K210993, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Oct 5, 2023Z-0548-2024Firm is expanding the existing recall RES 90457 for the Cerelink, initiated in June 2022, to include all CereLink ICP Extension Cables. The updated corrective action includes a design change to the extension cable to…Open
Jun 22, 2022Z-1395-2022Integra has received complaints associated with ICP readings drifting to -50 mmHg (out-of-range) and may manifest an error message "sensor or extension cable failure!" The firm has found that this is caused by…Open

Other GWM clearances

The newest 510(k)s for the same product code; their median review was 210 days; see every GWM device

Record

Type
Special
Received
Apr 2, 2021
Review panel
Neurology
Regulation
21 CFR 882.1620

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files