System, Imaging, Pulsed Doppler, Ultrasonic. 510(k) K102388, from Ge Medical System Israel , Ltd. (Wauwatosa, WI). Product code IYN, class 2.
As of Nov 20, 2026, K102388 is an FDA 510(k) held by Ge Medical System Israel , Ltd., substantially equivalent on Nov 4, 2010 after 73 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 73 days
- Recalls: 2
- Cited as a predicate by: 3 devices
K102385 NOV - 4 2010 The current modifications do not change the indications for use. As previously reported and cleared, the Vivid i/q ultrasound systems are intended for use by, or under the direction of, a qualified physician for ultrasound imaging and analysis in Abdominal/GYN; Urology; Fetal/OB; Small Organ (breast, testes, thyroid); Pediatric; Neonatal & Adult Cephalic; Cardiac (adult &…
- GE Vivid I Diagnostic Ultrasound, GE Vivid Q Diagnostic UltrasoundK092140 · Ge Medical Systems Israel, Ultrasound, Ltd. · Aug 21, 2009
- Modification To GE Vivid S5 and S6 Diagnostic UltrasoundK092079 · Ge Medical Systems Israel, Ultrasound, Ltd. · Aug 6, 2009
- SIGMA P5/ OMEGA P7/ LAMBDA P9 Portable Ultrasound Diagnostic ScannerK160343 · Beijing East Whale Imaging Technology Co., Ltd. · Apr 7, 2016
- Vivid I Diagnostic Ultrasound System, Vivid Q Diagnostic Ultrasound SystemK121062 · Ge Medical System Israel , Ltd. · Aug 17, 2012
- GE Vivid E9 Diagnostic Ultrasound Imaging SystemK120201 · Ge Vingmed Ultrasound AS · Apr 19, 2012
| Started | Recall | Status |
|---|---|---|
| Nov 10, 2022 | Z-0756-2023, Z-0757-2023Potential for batteries that have not been replaced at 2 years, as recommended in the Service Manual, they can fail or possibly emit smoke, or catch fire. | Open |
- Diagnostic Ultrasound System (Nuewa A20W); Diagnostic Ultrasound System (Nuewa A20); Diagnostic Ultrasound System…K261585 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 16, 2026
- Diagnostic Ultrasound System (Resona I10W);Diagnostic Ultrasound System (Resona I10 Exp);Diagnostic Ultrasound System…K261617 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 8, 2026
- V10 Diagnostic Ultrasound System; cV10 Diagnostic Ultrasound System; H10 Diagnostic Ultrasound System; XV10 Diagnostic…K263150 · Samsung Medison Co., Ltd. · Oct 8, 2026
- Voluson Expert 18; Voluson Expert 20; Voluson Expert 22K261933 · GE Medical Systems Ultrasound and Primary care Diagnostics, LLC · Oct 2, 2026
- EPIQ Inspira Series Diagnostic Ultrasound System; Affiniti Series Diagnostic Ultrasound SystemK262548 · Philips Ultrasound, LLC · Sep 25, 2026
- EVO X30 Diagnostic Ultrasound System; EVO X20 Diagnostic Ultrasound System; EVO X10 Diagnostic Ultrasound System; EVO…K263182 · Samsung Medison Co., Ltd. · Sep 25, 2026
- Vivid Explorer/Vivid Advanced/Vivid FocusK261313 · GE Medical Systems Ultrasound and Primary Care Diagnostics · Sep 2, 2026
- Digital Color Doppler Ultrasound System (Marvo 95/Marvo 95 Elite/Marvo 90/Marvo 90 CV/Marvo 90 Pro/Marvo 90 Exp/Marvo…K254027 · Sonoscape Medical Corp. · Aug 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Aug 23, 2010
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1550
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files