IYN: System, Imaging, Pulsed Doppler, Ultrasonic
FDA product code IYN. Class II, classified under 21 CFR 892.1550. What the classification flags say about Part 820 under the QMSR.
As of Nov 2, 2026, FDA product code IYN (System, Imaging, Pulsed Doppler, Ultrasonic) is Class II under 21 CFR 892.1550, reviewed through 510(k), with 1,189 linked 510(k), De Novo or BK numbers, 1 PMA and 300 recall product records.
Classification
- Product code
- IYN
- Device name
- System, Imaging, Pulsed Doppler, Ultrasonic
- Device class
- Class II
- Regulation
- 21 CFR 892.1550
- Review panel
- Radiology
- Premarket route
- 510(k)
- CGMP-exempt flag
- No
- Life-sustaining flag
- No
- Implant flag
- No
- Third-party review
- Candidate for third-party review
- Summary malfunction reporting
- Eligible
Data from openFDA as of 2 November 2026. Read the record on openFDA · FDA product code classification database
Part 820 requirements the flags point to
Part 820 rules for IYN
- CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
- Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
- Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
- Rule names this classRule names Class II.21 CFR 820.10(c) requires manufacturers of class II and class III devices to comply with clause 7.3 and its subclauses.21 CFR 820.10
- Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
- Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
- Complaint and record content21 CFR 820.35
- Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions
These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.
Clearances and recalls on record
- 510(k), De Novo and BK numbers linked
- 1,189 · Search these clearances
- PMA numbers linked
- 1
- Recall product records
- 300
- Adverse event reports
- Search MAUDE for IYN
Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.
Newest IYN clearances
- Diagnostic Ultrasound System (Nuewa A20W); Diagnostic Ultrasound System (Nuewa…: Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Oct 16, 2026
- Diagnostic Ultrasound System (Resona I10W);Diagnostic Ultrasound System (Resona…: Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Oct 8, 2026
- V10 Diagnostic Ultrasound System; cV10 Diagnostic Ultrasound System; H10…: Samsung Medison Co., Ltd., Oct 8, 2026
- Voluson Expert 18; Voluson Expert 20; Voluson Expert 22: GE Medical Systems Ultrasound and Primary care Diagnostics, LLC, Oct 2, 2026
- EPIQ Inspira Series Diagnostic Ultrasound System; Affiniti Series Diagnostic…: Philips Ultrasound, LLC, Sep 25, 2026
- EVO X30 Diagnostic Ultrasound System; EVO X20 Diagnostic Ultrasound System; EVO…: Samsung Medison Co., Ltd., Sep 25, 2026
- Vivid Explorer/Vivid Advanced/Vivid Focus: GE Medical Systems Ultrasound and Primary Care Diagnostics, Sep 2, 2026
- Digital Color Doppler Ultrasound System (Marvo 95/Marvo 95 Elite/Marvo 90/Marvo…: Sonoscape Medical Corp., Aug 24, 2026
- Venue Go: GE Medical Systems Ultrasound and Primary care Diagnostics, LLC, Aug 7, 2026
- Alturion Series Diagnostic Ultrasound System: Philips Ultrasound, LLC, Aug 4, 2026
Search all 7,098 product codes, or read the guide to the Part 820 rules behind these flags.
Check your quality documents against Part 820