Xper Information Management and Flex Cardio Physiomonitoring Systems
Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms). 510(k) K101571, from Witt Biomedical Corp (Melbourne, FL). Product code MWI, class 2.
As of Nov 20, 2026, K101571 is an FDA 510(k) held by Witt Biomedical Corp, substantially equivalent on Oct 26, 2010 after 144 days, with 8 recalls tied to it in FDA's recall database.
- Review time: 144 days
- Recalls: 8
- Cited as a predicate by: 2 devices
The physiomonitoring system is intended for use by professional healthcare providers for complete physiologic/hemodynamic monitoring. The system may be used to display and analyze surface ECG (electrocardiogram), respiration, invasive pressure, pulse oximetry (\mathrm{SpO}_{2}) , end tidal CO_{2 (ETCO _{2 ), fractional flow reserve (FFR), non-invasive blood pressure (NIBP), surface body…
- Xper Information Management/Physiomonitoring 5 System And/Or Vascular 5, Patient Care Console and Central StationK063840 · Witt Biomedical Corp · Feb 6, 2007
- Mac-Lab/Cardiolab Ep/Combolab SystemK050093 · Ge Medical Systems Information Technologies · May 13, 2005
- Poise DataengineK040969 · Poise Technology Corporation · Jun 8, 2004
- NewcorK020440 · Siemens Medical Systems, Inc. · Dec 3, 2002
- Integriti Patient MonitorK980688 · Alliance Instruments · Mar 16, 1999
- Philips Hemodynamic Application R1.0K181311 · Philips Medical Systems Nederlands B.V. · Sep 7, 2018
- McKesson Cardiology HemoK131497 · Mckesson Israel , Ltd. · Dec 5, 2013
| Mar 29, 2021 | Z-1517-2021Performance issues with the Xper Flex Cardio Physio Monitoring System include: potential delay of up to 10 seconds in displaying ECG, invasive blood pressure and other parameters; patient weight is rounded to the… | Open |
| Nov 15, 2018 | Z-0614-2019There are 3 issues: 1) Under certain conditions, real time waveforms may not be accurately plotted or displayed. 2) The oxygen saturation (SpO2) numeric value displayed on the device may freeze. 3) In auto cycle mode,… | Terminated |
| Sep 24, 2018 | Z-0462-2019The Invasive Blood Pressure (IBP) numeric values will freeze on the display when any of the following functions are performed: change an IBP Site Label using the Site Label icon or the keyboard, activate or deactivate… | Completed |
| Aug 3, 2018 | Z-3192-2018Released with an incorrect, older firmware version installed. May result in intermittent loss of ECG monitoring, inaccurate ECG amplitude display and or auxiliary output, and inaccurate heart rate (HR) displayed due to… | Terminated |
| Nov 20, 2017 | Z-2115-2018While in Full Disclosure playback, a user may inadvertently close the Full Disclosure Control Window using the ESC key function, instead of pressing the X icon in the upper right corner of this window. | Open |
| Aug 18, 2017 | Z-0263-2018Intermittent communication between the host system and the FlexCardio | Terminated |
| Aug 11, 2017 | Z-0082-2018Intermittent communication between the host system and the Flex Cardio | Terminated |
| Oct 19, 2015 | Z-2760-2016Display of SpO2 and Non-Invasive Blood Pressure (NIBP) Measurements May Freeze | Terminated |
- Sensinel Cardiopulmonary Management (CPM) SystemK260801 · Analog Devices · Oct 16, 2026
- Vital Signs Monitor (CLEO2)K260438 · Infinium Medical, Inc. · Aug 14, 2026
- Masimo Root Monitoring SystemK253417 · Masimo Corporation · Aug 12, 2026
- BioTracker 2.0K253306 · Biotracker, LLC · Jun 26, 2026
- Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300, 1-300-0400)K253196 · Midmark Corporation · Jun 12, 2026
- c-med0 alphaK253436 · Cosinuss GmbH · Apr 30, 2026
- WAVE Clinical Platform (2.0.000)K250135 · Baxter Healthcare Corp/ Excel Medical · Jan 16, 2026
- QMAPP® (Hemo, Hemo Lite, PCM, GO, Hybrid)K241766 · Fysicon BV · Aug 27, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 4, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files