McKesson Cardiology Hemo
Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms). 510(k) K131497, from Mckesson Israel , Ltd. (Alpharetta, GA). Product code MWI, class 2.
As of Nov 19, 2026, K131497 is an FDA 510(k) held by Mckesson Israel , Ltd., substantially equivalent on Dec 5, 2013 after 195 days, with 10 recalls tied to it in FDA's recall database.
- Review time: 195 days
- Recalls: 10
- Cited as a predicate by: 3 devices
McKesson Cardiology™ Hemo is intended for complete physiological/hemodynamic monitoring, clinical data acquisition, medical image and data processing, and analytical assessment. McKesson Cardiology™ Hemo is also intended for patient/procedural data management, such as documentation, logging, reporting, trending, storing, reviewing, carrying out clinical calculations and exporting various…
- WindsurferK050561 · Medcon , Ltd. · May 4, 2005
- Xper Information Management and Flex Cardio Physiomonitoring SystemsK101571 · Witt Biomedical Corp · Oct 26, 2010
- QMAPP® (Hemo, Hemo Lite, PCM, GO, Hybrid)K241766 · Fysicon BV · Aug 27, 2025
- Change Healthcare Cardiology Hemodynamics™K230881 · Change Healthcare Israel , Ltd. · Sep 11, 2023
- QMAPP Amplifier; QMAPP Hemodynamic Monitoring System; QMAPP PCM; QMAPP GO; QMAPP EPK170032 · Fysicon BV · Sep 8, 2017
| May 22, 2025 | Z-2071-2025Due to complaints, software update may cause software to unexpectedly shutdown. | Open |
| Dec 2, 2024 | Z-0957-2025, Z-0958-2025Software defect concerning autosave mechanism may result in the clinician administering incorrect medication(s). | Open |
| Aug 21, 2024 | Z-0128-2025, Z-0126-2025A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment.… | Open |
| Mar 25, 2019 | Z-1490-2019, Z-1489-2019users are not notified of procedure medication discrepancies between the Vitals and Meds, the Procedure Notes and Patient Common Data screens in Horizon/McKesson Cardiology Hemo" (Hemo). The discrepancy may also affect… | Terminated |
| Mar 12, 2018 | Z-2968-2018Change Healthcare has identified an issue where, under certain circumstances, the Real Time Monitor (RTM) may not display physiological signals. | Terminated |
| Aug 27, 2014 | Z-0042-2015Software Error: The McKesson Cardiology Hemo calculation section incorrectly converts the Hemoglobin value before it is utilized in the applicable formula calculations. | Terminated |
| Jun 25, 2014 | Z-0093-2015McKesson Cardiology Hemo front-end parameter boxes must undergo annual maintenance testing to establish the proper functioning of the parameter boxes, and to identify in a timely manner whether a parameter box is out of… | Terminated |
- Sensinel Cardiopulmonary Management (CPM) SystemK260801 · Analog Devices · Oct 16, 2026
- Vital Signs Monitor (CLEO2)K260438 · Infinium Medical, Inc. · Aug 14, 2026
- Masimo Root Monitoring SystemK253417 · Masimo Corporation · Aug 12, 2026
- BioTracker 2.0K253306 · Biotracker, LLC · Jun 26, 2026
- Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300, 1-300-0400)K253196 · Midmark Corporation · Jun 12, 2026
- c-med0 alphaK253436 · Cosinuss GmbH · Apr 30, 2026
- WAVE Clinical Platform (2.0.000)K250135 · Baxter Healthcare Corp/ Excel Medical · Jan 16, 2026
- QMAPP® (Hemo, Hemo Lite, PCM, GO, Hybrid)K241766 · Fysicon BV · Aug 27, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 24, 2013
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files