ABL90 Flex Series
Electrode, Ion Specific, Potassium. 510(k) K092686, from Radiometer Medical Aps (Bronshoj, DK). Product code CEM, class 2.
As of Nov 17, 2026, K092686 is an FDA 510(k) held by Radiometer Medical Aps, substantially equivalent on Aug 6, 2010 after 338 days, with 10 recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 6, 2010
- Review time: 338 days
- Recalls: 10
- Cited as a predicate by: 6 devices
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Modification To ABL800 FlexK050869 · Radiometer Medical Aps · Aug 11, 2005
- ABL800 FlexK041874 · Radiometer Medical Aps · Oct 8, 2004
- ABL-700 Series, Model Abl 7XX (Various Models)K002290 · Radiometer Medical A/S · Sep 13, 2000
- NPT7 Series Ph/Blood Gas And Co-Oximetry SystemK982928 · Radiometer America, Inc. · Jan 6, 1999
- QUALICHECK5+ Models S7730, S7740, S7750, S7760K980135 · Radiometer America, Inc. · Jan 28, 1998
Cited as a Predicate
6 later 510(k) summaries name this device as a predicate- ABL90 FLEX PLUS SystemK241037 · Radiometer Medicals Aps · Jan 14, 2025
- OPTI® B-Lac CassetteK200986 · Opti Medical Systems, Inc. · Aug 2, 2021
- ABL90 FlexK130144 · Radiometer Medical Aps · Jul 31, 2013
- ABL90 FlexK122642 · Radiometer Medical Aps · Oct 26, 2012
- ABL90 FlexK120197 · Radiometer Medical Aps · Mar 19, 2012
- ABL90K111897 · Radiometer Medical Aps · Jul 19, 2011
Recalls
Recalls FDA ties to K092686, newest first; each opens FDA's recall record| Mar 21, 2025 | Z-1659-2025ABL90 FLEX and ABL90 FLEX PLUS analyzers running with Radiometer Windows 10 versions RWIN10 1.0 and RWIN10 1.1 may unexpectedly freeze (the analyzer ceases to operate) during a sample measurement. The analyzer software… | Open, Classified |
| Apr 14, 2021 | Z-1858-2021Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed. | Open, Classified |
| Apr 14, 2021 | Z-1856-2021Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed. | Open, Classified |
| Feb 3, 2020 | Z-1760-2020The firm received reports of occurrences where the barcode reader misinterpreted the contents of a locally printed barcode label used for entering patient ID or accession number into the analyzer in connection with a… | Terminated |
| Nov 21, 2019 | Z-2139-2020The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcomponent of the optical system which measures ctHb and derivates. In a cuvette with light shunt, some of the received light has… | Terminated |
| Jul 10, 2019 | Z-2320-2019Software Security; The action is being initiated because of software security vulnerabilities with the firm's analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical… | Terminated |
| Jan 26, 2017 | Z-1462-2017Reports that the sample type "cord blood" has been changed into the two sample types "cord blood arterial" and "cord blood venous. | Terminated |
| Oct 15, 2013 | Z-0816-2014RADIOMETER become aware that if the ABL90 FLEX is tilted, this may potentially cause a negative bias on sodium (Na+) results. | Terminated |
| Jan 12, 2011 | Z-2112-2011Following the receipt of two (2) reported customer complaints, the firm determined that the current operating software for their ABL 90 Analyzer does not prevent the further use of the sensor cassette when there is the… | Terminated |
| Nov 1, 2010 | Z-1011-2011Due to a software error, a patient mix up can occur on the ABL90. If a sample is pre-registered and the sample "fails" the next result will inherit the patient data from the previous result. | Terminated |
Other CEM Clearances
The newest 510(k)s for the same product code; their median review was 273 days; see every CEM device- ISE indirect K for Gen.2; ISE indirect Na for Gen.2; ISE indirect Cl for Gen.2; cobas pro…K253491 · Roche Diagnostics · Feb 12, 2026
- ABL90 FLEX PLUS SystemK241037 · Radiometer Medicals Aps · Jan 14, 2025
- EasyStat 300K220396 · Medica Corporation · Sep 26, 2023
- ISE ElectrodesK230890 · Randox Laboratories, Ltd. · Sep 8, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 2, 2009
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1600
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files