Sterrad NX Sterilizer
Sterilizer, Chemical. 510(k) K042116, from Advanced Sterilization Products (Irvin, CA). Product code MLR, class 2.
As of Nov 23, 2026, K042116 is an FDA 510(k) held by Advanced Sterilization Products, substantially equivalent on Apr 22, 2005 after 260 days, with 10 recalls tied to it in FDA's recall database.
- Review time: 260 days
- Recalls: 10
- Cited as a predicate by: 5 devices
The STERRAD® NX Sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures. The STERRAD sterilization process is a multiphase sterilization process that utilizes a combination of exposure to hydrogen peroxide vapor and plasma to affect sterilization.
- STERRAD NX SterilizerK162007 · Advanced Sterilization Products · Feb 16, 2017
- STERRAD® NX Sterilizer with ALLClear™ TechnologyK160818 · Advanced Sterilization Products · Sep 27, 2016
- STERRAD NX Sterilizer, STERRAD 100NX SterilizerK142454 · Advanced Sterilization Products · Apr 3, 2015
- Amsco V-Pro Max Low Temperature Sterilization SystemK102330 · STERIS Corporation · Aug 12, 2011
- Sterrad 100NX SterilizerK071385 · Advanced Sterilization Products · Nov 29, 2007
| Jan 9, 2017 | Z-1197-2017Advanced Sterilization Products (ASP) has identified that in a rare sequence of events following an external power outage, the system door interlock can be become disengaged during system reboot for a 20-second duration. | Terminated |
| Nov 4, 2014 | Z-0845-2015Advanced Sterilization Products is recalling the STERRAD System cassettes because the the leak indicator on the STERRAD System cassettes packaging may not function properly after exposure to hydrogen peroxide. | Terminated |
| Dec 16, 2013 | Z-0744-2014Advanced Sterilization Products (ASP) is recalling the STERRAD NX, STERRAD 50, and STERRAD 100S Sterilization Systems because some healthcare workers detected odors or smells possibly emanating from STERRAD Systems. | Terminated |
| Nov 11, 2013 | Z-0403-2014Advanced Sterilization Products (ASP) is recalling the STERRAD NX and STERRAD 100NX sterilization systems because ASP has determined that the bronchoscopes may contain a polyurethane material in the suction channel… | Terminated |
| Jun 19, 2012 | Z-2338-2012Advanced Sterilization Products (ASP) is recalling (removing) the Sterrad 100S and Sterrad NX System cassettes because the camera used to verify printing on the Sterrad System cassettes was inadvertently disabled. The… | Terminated |
| Mar 9, 2009 | Z-1420-2009ASP has identified a secondary, lower-occurring cause of oil mist within certain STERRAD NX Systems and STERRAD 50 Systems due to potentially defective oil fill plugs. | Terminated |
| Dec 10, 2008 | Z-0468-2012Advanced Sterilization Products (ASP) has discovered a defect in the barcode labeling of the STERRAD NX System Cassettes 10133, Lot #08I032. This is the only lot number affected by this action. The barcodes for Lot… | Terminated |
| Oct 7, 2008 | Z-0484-2009ASP has discovered a component defect in some of the UV lamp power supplies used in certain STERRAD NX Sterilizers. This defect can potentially cause the Hydrogen Peroxide Monitor to give inaccurate readings. | Terminated |
| Feb 25, 2008 | Z-1631-2008Oil mist filter fails allowing oil mist to be emitted into the vicinity of the sterilizer, which may result in the release of a mist, "haze," or "smoke." | Terminated |
| Nov 12, 2007 | Z-0844-2008Outdated Compatibility Lists: Recalling firm has decided to discontinue dissemination of Compatible Medical Device Reference Lists and instrument assessment activities | Terminated |
- V-Pro maX 2 Low Temperature Sterilization SystemK263530 · Steris · Oct 29, 2026
- STERRAD 100NX Sterilization System with ALLClear Technology (10104)K252843 · Advanced Sterilization Products, Inc. · Apr 15, 2026
- STERRAD® 100NX Sterilizer with ALLClear™ Technology (10104)K250802 · Advanced Sterilization Products, Inc. · Apr 14, 2025
- LOWTEM Crystal 120K231893 · Lowtem Co., Ltd. · Sep 18, 2024
- STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™ Cycle (10104); APTIMAX™ Instrument Tray for ULTRA GI™…K234082 · Advanced Sterilization Products · Jul 5, 2024
- SteroScope® Sterilization Technology SystemK233762 · Ideate Medical, Inc. · Jun 27, 2024
- V-PRO maX 2 Low Temperature Sterilization SystemK233065 · Steris · Oct 20, 2023
- V-PRO maX 2 Low Temperature Sterilization SystemK223476 · STERIS Corporation · Aug 7, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 5, 2004
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.6860
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files