V-PRO maX 2 Low Temperature Sterilization System
Sterilizer, Chemical. 510(k) K223476, from STERIS Corporation (Mentor, OH). Product code MLR, class 2.
As of Nov 19, 2026, K223476 is an FDA 510(k) held by STERIS Corporation, substantially equivalent on Aug 7, 2023 after 262 days, with no recalls tied to it in FDA's recall database.
- Review time: 262 days
- Recalls: 0
- Cited as a predicate by: 1 device
The V-PRO maX 2 Low Temperature Sterilization System using VAPROX HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The preprogrammed sterilization cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues.
- V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization SystemK222093 · Steris · Sep 9, 2022
- V-PRO maX 2 Low Temperature Sterilization SystemK233065 · Steris · Oct 20, 2023
- V-Pro maX 2 Low Temperature Sterilization SystemK263530 · Steris · Oct 29, 2026
- STERRAD 100NX Sterilization System with ALLClear Technology (10104)K252843 · Advanced Sterilization Products, Inc. · Apr 15, 2026
- STERRAD® 100NX Sterilizer with ALLClear™ Technology (10104)K250802 · Advanced Sterilization Products, Inc. · Apr 14, 2025
- LOWTEM Crystal 120K231893 · Lowtem Co., Ltd. · Sep 18, 2024
- STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™ Cycle (10104); APTIMAX™ Instrument Tray for ULTRA GI™…K234082 · Advanced Sterilization Products · Jul 5, 2024
- SteroScope® Sterilization Technology SystemK233762 · Ideate Medical, Inc. · Jun 27, 2024
- V-PRO maX 2 Low Temperature Sterilization SystemK233065 · Steris · Oct 20, 2023
- STERLINK plus Sterilizer with STERLOAD Cassette, Tyvek Roll with CI for STERLINK Sterilizer, Terragene Bionova SCBI…K231169 · Plasmapp Co,., Ltd. · May 25, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 18, 2022
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.6860
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files