Sterrad 50 & Sterrad 100S Sterilizers

Sterilizer, Ethylene-Oxide Gas. 510(k) K023290, from Advanced Sterilization Products (Irvin, CA). Product code FLF, class 2.

As of Nov 25, 2026, K023290 is an FDA 510(k) held by Advanced Sterilization Products, substantially equivalent on Apr 3, 2003 after 183 days, with 9 recalls tied to it in FDA's recall database.

  • Review time: 183 days
  • Recalls: 9
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

This Premarket Notification is to expand the Indications for Use for the STERRAD 50 Sterilizer (K981625) and the STERRAD 100S Sterilizer (K991999) to include titanium as a compatible material and to expand the lumen sizes to include medical devices with only a single stainless steel lumen in the following configurations: - An inside diameter of 1 mm or larger and a length of 125 mm or shorter -…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K023290, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Nov 4, 2014Z-0842-2015, Z-0843-2015Advanced Sterilization Products is recalling the STERRAD System cassettes because the the leak indicator on the STERRAD System cassettes packaging may not function properly after exposure to hydrogen peroxide.Terminated
Dec 16, 2013Z-0746-2014, Z-0744-2014, Z-0745-2014Advanced Sterilization Products (ASP) is recalling the STERRAD NX, STERRAD 50, and STERRAD 100S Sterilization Systems because some healthcare workers detected odors or smells possibly emanating from STERRAD Systems.Terminated
Mar 9, 2009Z-1419-2009ASP has identified a secondary, lower-occurring cause of oil mist within certain STERRAD NX Systems and STERRAD 50 Systems due to potentially defective oil fill plugs.Terminated
Oct 17, 2008Z-0340-20091) Inability of the sterilizer to detect when an injection takes place without hydrogen peroxide being transferred to the vaporizer bowl. This situation can result in a cycle completion with the injection of…Terminated
Feb 25, 2008Z-1629-2008, Z-1628-2008Oil mist filter fails allowing oil mist to be emitted into the vicinity of the sterilizer, which may result in the release of a mist, "haze," or "smoke."Terminated

Record

Type
Traditional
Received
Oct 2, 2002
Review panel
General Hospital
Regulation
21 CFR 880.6860

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files