Innova and Innova 2000 S
Interventional Fluoroscopic X-Ray System. 510(k) K022322, from Ge Medical Systems, Inc. (Waukesha, WI). Product code OWB, class 2.
As of Nov 19, 2026, K022322 is an FDA 510(k) held by Ge Medical Systems, Inc., substantially equivalent on Oct 8, 2002 after 83 days, with 7 recalls tied to it in FDA's recall database.
- Review time: 83 days
- Recalls: 7
- Cited as a predicate by: 3 devices
The Digital Fluoroscopic Imaging Systems are indicated for use in generating fluoroscopic images of human anatomy for diagnostic and interventional cardiac angiography, and optionally, rotational cardiac angiography procedures. It is intended to replace fluoroscopic images obtained through the image intensifier technology.
- Lcv+ Version 2K993037 · Ge Medical Systems, Inc. · Feb 14, 2000
- Advantx LcaK945375 · GE Medical Systems · Jan 30, 1995
- LC, Cardiac Positioner #B5078AK890348 · General Electric Co. · Feb 27, 1989
- Cs-Series-FpK100102 · Omega Medical Imaging, Inc. · Aug 31, 2010
- Innova 2100K050489 · Ge Medical Systems, LLC · Mar 11, 2005
- Innova 3100K031637 · GE Medical Systems · Aug 22, 2003
| Nov 21, 2016 | Z-0904-2017GE Healthcare is conducting a recall due to the potential fall of aged CRT monitors - Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems. | Terminated |
| Dec 18, 2015 | Z-0763-2016GE Healthcare has recently become aware of a reported incident in which a Mavig suspension arm with monitor assembly fell to the floor. | Terminated |
| Aug 16, 2013 | Z-0021-2014GE Healthcare has become aware of a potential safety issue involving missing screws in the overhead Video Monitor Suspension of the Advantx, Innova 2000, Innova 2100IQ, Innova 3100, Innova 3100IQ, Innova 4100, Innova… | Terminated |
| Jun 10, 2010 | Z-2238-2010A hardware component (potentiometer and encoder)mismatch in Innova 2000 digital fluoroscopic imaging systems may cause a Source to Image Distance (SID) failure, which will cause the imager to fail to detect the distance… | Terminated |
| Dec 22, 2009 | Z-0620-2010Potential table rotation of Omega IV and Omega V tables affecting Advantx-E and Innova 2000, 2100IQ, 3100, 3100IQ, 4100, 4100IQ, 2121IQ and 3131IQ cardiovascular X-ray imaging systems. Due to potential weakness of some… | Terminated |
| Jul 25, 2008 | Z-2435-2008The charger and / or battery of the PDB may fail earlier than expected with no advance warning and thus cause the system to shut down. | Terminated |
| Mar 6, 2006 | Z-0896-06Incorrect screws were used for mounting the detector which may lead to a possible part falling onto a patient. | Terminated |
- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;Extron 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 17, 2002
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files