System, X-Ray, Tomography, Computed. 510(k) K010817, from Philips Medical Systems (Cleveland), Inc. (Cleveland, OH). Product code JAK, class 2.
As of Nov 19, 2026, K010817 is an FDA 510(k) held by Philips Medical Systems (Cleveland), Inc., substantially equivalent on Jun 15, 2001 after 88 days, with 12 recalls tied to it in FDA's recall database.
- Review time: 88 days
- Recalls: 12
- Cited as a predicate by: 5 devices
- SpotLight CTK161066 · Arineta , Ltd. · Aug 10, 2016
- Acqsim-Multislice-Ct, Model 453567042271K033357 · Philips Medical Systems (Cleveland), Inc. · Jan 9, 2004
- Philips Plus Computed Tomography SystemK033326 · Philips Medical Systems, Inc. · Oct 29, 2003
- Gemini Imaging SystemK013521 · Adac Laboratories · Nov 7, 2001
- MX8000 Idt CT SystemK012009 · Marconi Medical Systems, Inc. · Sep 13, 2001
| May 1, 2021 | Z-1979-2021Significant wear of the Monitor Bracket Assembly shaft goes unrecognized could potentially lead to the Monitor Bracket Assembly detaching from the Suspension Arm and result in potential hazard for the monitor to fall… | Open |
| Mar 16, 2015 | Z-1647-2015The firm was informed that while raising the patient couch on the system to perform an exam, the couch unexpectedly descended to the lowest point without being commanded to do so. | Terminated |
| Apr 1, 2014 | Z-1722-2014A customer reported that the table top had become free floating. A Field Service Engineer (FSE) confirmed that the service latch had become disengaged. | Terminated |
| Dec 20, 2012 | Z-0945-2013Philips Healthcare received reports from the field stating the patient table on a system had an unexpected downward movement while a patient was on the table. Philips has determined the cause was a malfunction of the… | Terminated |
| Jun 3, 2011 | Z-2914-2011Philips Medical Systems decided to conduct a recall/field correction of the patient support vertical brake hub component in all of their CT MX8000 Dual v. Exp Computed Tomography X-Ray System scanners due to a component… | Terminated |
| Sep 23, 2008 | Z-0597-2009The product is being recalled because the patient support may travel downwards without being commanded to move. | Terminated |
| Nov 6, 2006 | Z-0014-2007A potential anomaly was identified on the CT subsytem, which could result in the radiation dose being different than the calculated dose reported to the operator. | Terminated |
| Dec 27, 2005 | Z-2709-2014The system has a gap that can appear between the upper and lower tilt stand covers. The fingers may be squeezed if a person was to place them in this region while the gantry was tilting from an angle to zero tilt angle. | Terminated |
| Mar 11, 2005 | Z-1414-05, Z-1412-05, Z-1410-05When two product applications called Flip and Secondary Capture are used together, it is possible for image orientation labels to be incorrect. | Terminated |
| Apr 2, 2003 | Z-0836-03Patient images may be incorrectly stored in the archive directory of a different patient. | Terminated |
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 19, 2001
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files