Arrowg +Ard Blue Plus Antimicrobial Multi-Lumen Central Venous Catheter

Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days. 510(k) K993691, from Arrow Intl., Inc. (Reading, PA). Product code FOZ, class 2.

As of Nov 20, 2026, K993691 is an FDA 510(k) held by Arrow Intl., Inc., substantially equivalent on Mar 8, 2000 after 128 days, with 22 recalls tied to it in FDA's recall database.

  • Review time: 128 days
  • Recalls: 22
  • Cited as a predicate by: 5 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The ARROWg*ard Blue Plus™ antimicrobial catheter is indicated in the short-term (<30 day) treatment of diseases or conditions requiring central venous access, including, but not limited to the following: • multiple peripheral sites for IV access • lack of usable peripheral IV sites • central venous pressure monitoring • total parenternal nutrition (TPN) - incompatible medications • multiple…

Cited as a predicate

5 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K993691, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 21, 2026Z-2376-2026Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if…Open
Jan 6, 2021Z-1106-2021The lidstock / information card on the kits correctly states the product code as CDC-45703-1A. The banner card on the side of the kit may incorrectly state the product code as CDC-15703-1A and not identify the product…Terminated
Jul 18, 2019Z-0192-2020Arrow AGB+ Multi-Lumen CVC Kit - lidstock incorrectly states within CDC-45703-1A a catheter 20cm in length. The banner card correctly states the product is CDC-42703-1A with a catheter 16cm in lengthTerminated
Sep 21, 2018Z-0468-2019The products labeling contains inconsistencies. In certain instances, the lidstock, banner card and shipper label state that the Spring Wire Guide (SWG) within is .032 rather than the correct SWG size .025 . For other…Terminated
Aug 30, 2018Z-0282-2019The product was shipped after its expiry date due to a system error. The product lidstock identifies the correct expiration date however the accompanying purchase order shipping documentation identifies an incorrect…Terminated
Apr 11, 2018Z-2005-2018, Z-2002-2018, Z-2004-2018, Z-2001-2018, Z-2003-2018Product sterility may be compromised due to unsealed packaging.Terminated
Dec 22, 2017Z-1335-2018Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.Terminated
Dec 21, 2017Z-1152-2018Certain lots may be missing information at the bottom of the lid including the lot number, expiration date, and Unique Device Identification (UDI) information.Terminated
Oct 17, 2017Z-0656-2018These finished good kits may contain the incorrect Springwire Guide (SWG).Terminated
May 9, 2017Z-2332-2017Arrow International is recalling the affected product because the packaging may not be completely sealed, which may compromise sterility.Terminated
Jul 17, 2013Z-1507-2014Arrow is recalling the Arrowgard Blue Plus Antimicrobial Multi-lumen Central Venous Catheter due to a labeling inconsistency. One portion of the lidstock states that the kit contains 8.5FR x 16CM catheter, while the…Terminated
Jul 29, 2010Z-2493-2010Incorrectly assembled 18 Ga x 2 1/2 Introducer NeedleTerminated
Nov 24, 2009Z-0788-2010, Z-0786-2010, Z-0785-2010, Z-0787-2010Q-Syte Component contained in kits was recalled by manufacturer due to the potential for embolism if used with a central venous catheter.Terminated
Feb 11, 2009Z-1498-2009Leakage: Material not lipid resistant, may crack and/or leak. Use of this device with lipid containing solutions or 70% isopropyl alcohol may cause leakage or air embolism.Terminated
Sep 27, 2004Z-0059-05Labeling error. Kits contains the correct components for AK-42802-SK but may have a package label indicating that it is product number AK-22802-SKTerminated

Other FOZ clearances

The newest 510(k)s for the same product code; their median review was 228 days; see every FOZ device

Record

Type
Traditional
Received
Nov 1, 1999
Review panel
General Hospital
Regulation
21 CFR 880.5200

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files