Sunder Central Venous Catheter Kit, Models SD-3L55F30J and SD-3L70F30J
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days. 510(k) K024007, from Sunder Biomedical Tech. Co., Ltd. (Taichung City, TW). Product code FOZ, class 2.
As of Nov 20, 2026, K024007 is an FDA 510(k) held by Sunder Biomedical Tech. Co., Ltd., substantially equivalent on Jul 14, 2003 after 222 days, with no recalls tied to it in FDA's recall database.
- Review time: 222 days
- Recalls: 0
- Cited as a predicate by: 1 device
The triple lumen central venous Catheter is intended for vascular access infusion and withdrawal of blood, blood products, and fluids, central venous blood pressure monitoring and continuous or intermittent drug infusion. ● Patients requiring multiple sites for IV access. ● Patients lacking useable peripheral IV sites. ● Patients requiring central venous pressure monitoring.
- Arrowg +Ard Blue Plus Antimicrobial Multi-Lumen Central Venous CatheterK993691 · Arrow Intl., Inc. · Mar 8, 2000
- Able Central Venous CatheterK070451 · Foshan Nanhai Bai HE Medical Technology Co., Ltd. · Jul 31, 2007
- Medican Alpha, Medican, Mediflon, Mediflon Quick, Medican Alpha Safety, Medican Safety, Mediflon Safety, Mediflon…K260631 · Global Medikit Limited · Nov 5, 2026
- Ruby Intravascular CatheterK260432 · Venocare, Inc. · Sep 2, 2026
- Unimpregnated Central Venous CatheterK260165 · Spectrum Vascular · Aug 10, 2026
- ClearSafe Closed SystemK261041 · MedSource Labs, LLC · Jul 10, 2026
- MedSource QuickSafe™ Safety IV Catheter; MedSource PurSafe™ Safety IV CatheterK260539 · MedSource Labs, LLC · Jul 9, 2026
- Introcan Safety® Deep Access XL IV CatheterK253235 · B.Braun Medical, Inc. · May 15, 2026
- BD Insyte™ IV CatheterK252137 · Becton Dickinson Infusion Therapy Systems, Inc. · Apr 2, 2026
- Polywin Safety (14G x 51mm; 16G x 51mm; 18G x 64mm; 20G x 64mm; 20G x 45mm; 22G x 64mm; 22G x 45mm; 24G x 32mm; 24G x…K252513 · Poly Medicure Limited · Apr 1, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 4, 2002
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5200
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files