Meridian Hemodialysis Machine, Model 5M5576
Dialyzer, High Permeability With Or Without Sealed Dialysate System. 510(k) K992894, from Baxter Healthcare Corp (Mcgaw Park, IL). Product code KDI, class 2.
As of Nov 28, 2026, K992894 is an FDA 510(k) held by Baxter Healthcare Corp, substantially equivalent on Nov 24, 1999 after 89 days, with 5 recalls tied to it in FDA's recall database.
- Review time: 89 days
- Recalls: 5
- Cited as a predicate by: 2 devices
The Baxter Meridian machine is part of a high permeability hemodialysis system which consists of a controlled dialysate delivery system that incorporates an ultrafiltration controller to prevent excessive loss of water from the patient's blood, an extracorporeal blood set and a high permeability dialyzer.
- Heomdialysis Single Patient System (Sps) Model 650K883111 · Baxter Healthcare Corp · Feb 8, 1989
- Sps 1550 Single Needle Patient SystemK922757 · Baxter Healthcare Corp · Feb 13, 1995
- Meridian Hemodialysis Machine, Model 5M5576K053539 · Baxter Healthcare Corporation · May 24, 2006
- Aurora System 1000 Series Home Self-Care Single Patient Delivery System; Models- Sys 1000, L3 With N100 Arm, 4B SoftwareK013562 · Baxter Healthcare Corp · Dec 12, 2002
| Sep 6, 2006 | Z-0169-2007The Meridian pump is less likely to detect small pressure changes, which may indicate the presence of a post-pump tubing kink, when using pre-pump arterial pressure monitoring. | Terminated |
| Sep 28, 2005 | Z-0275-06Inadequate instructions for routing single tubing lines through the double-tubing clips on the front of the instrument to eliminate the risk of kinks in the tubing, which have been associated with a death and a serious… | Terminated |
| Dec 2, 2004 | Z-0299-05The instrument power cord may become disconnected from the instrument and pose a fire or electrical shock hazard. | Terminated |
| Mar 10, 2004 | Z-0758-04Microbubbles of air in the extracorporeal blood circuit during hemodialysis therapy on the Meridian. | Terminated |
| Oct 3, 2003 | Z-0947-05The saline bags may inappropriately empty/fill during the recirculation mode of the hemodialysis system. | Terminated |
- multiFiltratePRO SystemK261203 · Fresenius Medical Care Renal Therapies Group, LLC · Oct 19, 2026
- Careflux H60;Careflux H70;Careflux V500K261267 · Fresenius Medical Care Renal Therapies Group, LLC · Jul 24, 2026
- NxStage System One with NxViewK252377 · Fresenius Medical Care Renal Therapies Group, LLC · May 15, 2026
- Elisio™-HK260533 · Nipro Medical Corporation · Mar 19, 2026
- multiFlux 130 (F00013123); multiFlux 160 (F00013124)K252459 · Fresenius Medical Care Renal Therapies Group, LLC · Feb 10, 2026
- Tablo Hemodialysis System (PN-0008000, PN-0006000U)K253412 · Outset Medical, Inc. · Jan 26, 2026
- FX CorAL 40; FX CorAL 50K253518 · Fresenius Medical Care Renal Therapies Group, LLC · Dec 18, 2025
- Purema H Hemoconcentrator - PediatricK243920 · Medica USA, Inc. · Sep 19, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 27, 1999
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5860
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files