Regional Anesthesia Trays
Anesthesia Conduction Kit. 510(k) K965017, from Smiths Industries Medical Systems, Inc. (Keene, NH). Product code CAZ, class 2.
As of Nov 20, 2026, K965017 is an FDA 510(k) held by Smiths Industries Medical Systems, Inc., unknown on Mar 14, 1997 after 88 days, with 7 recalls tied to it in FDA's recall database.
- Review time: 88 days
- Recalls: 7
- Cited as a predicate by: 3 devices
SIMS' Regional Anesthesia Trays are used to administer to a patient regional or local anesthesia.
- Correctinject Safety System, Catheter Connector, Filter, Infusion Adaptor, Syringe KitK110053 · Smiths Medical Asd, Inc. · Sep 14, 2012
- Epifuse Catheter Connector, Model: 4909EK092657 · Smiths Medical Asd, Inc. · Nov 4, 2009
- Portex 24G Pediatric Epidural and Peripheral Block Anesthesia CatheterK033080 · Portex, Inc. · Mar 10, 2004
| Dec 19, 2025 | Z-1101-2026Affected lots of syringes may have a crack on the syringe collar, which may lead to delayed or repeated blood draw/fluid delivery. This issue may also lead to blood leakage during sampling of arterial blood or leakage… | Open |
| Oct 27, 2006 | Z-0211-2007Misbranded: Tray label states 26G x 5/8 inch, needle is 25 G x 1 inch | Terminated |
| Nov 17, 2005 | Z-0244-06, Z-0243-06, Z-0245-06, Z-0242-06Tray may contain holes compromising the sterility of the device | Terminated |
| Oct 10, 2003 | Z-0166-04Spinal trays labeled as containing a Whitacre 25g x 3.5' needle actually contain a Quincke 25g x 3.5' needle. | Terminated |
- Profoject™ LOR SyringeK261372 · CMT Health PTE., Ltd. · Sep 25, 2026
- Arrow 0.2 Micron Flat Filter, GVSK222341 · Arrow International, LLC · Feb 13, 2023
- BD Epilor SyringeK210983 · Becton, Dickinson and Company · May 19, 2022
- Plastic LOR SyringeK201356 · Jiangsu Caina Medical Co.,Ltd · Feb 12, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 16, 1996
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5140
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files