Correctinject Safety System, Catheter Connector, Filter, Infusion Adaptor, Syringe Kit
Anesthesia Conduction Kit. 510(k) K110053, from Smiths Medical Asd, Inc. (Keene, NH). Product code CAZ, class 2.
As of Nov 19, 2026, K110053 is an FDA 510(k) held by Smiths Medical Asd, Inc., substantially equivalent on Sep 14, 2012 after 616 days, with no recalls tied to it in FDA's recall database.
- Review time: 616 days
- Recalls: 0
- Cited as a predicate by: 3 devices
CorrectInject™ Safety System The CorrectInject™ Safety System is intended for the injection of local or regional anesthetics, narcotics or other medications indicated for neuraxial injection. The system consists of components that have a unique non-Luer taper that allows connection of compatible CorrectInject™ components that, when used together as a system, help reduce the risk of mis-connection…
- Regional Anesthesia TraysK965017 · Smiths Industries Medical Systems, Inc. · Mar 14, 1997
- Epifuse Catheter Connector, Model: 4909EK092657 · Smiths Medical Asd, Inc. · Nov 4, 2009
- Portex Epidural Filter, Model 100/386/010, Various Standard and Custom TraysK083451 · Smiths Medical Asd, Inc. · Mar 4, 2009
- Becton Dickinson SyringeK980987 · Bd Becton Dickinson Vacutainer Systems Preanalytic · Jun 11, 1998
- B-D Filter NeedleK801343 · Bd Becton Dickinson Vacutainer Systems Preanalytic · Jun 20, 1980
- Portex NRFit Epidural Needles, Portex NRFit Spinal Needles, Portex NRFit Loss of Resistance (L.O.R.) Syringes., Portex…K172410 · Smiths Medical Asd, Inc. · Jun 1, 2018
- DASH 6 NRFit Lock Syringe + Accessories, DASH 6 NRFit Slip Syringe + Accessories, DASH 6 NRFit Plastic LOR Syringe +…K170900 · Intervene Group, Ltd. · Nov 9, 2017
- CADD® Infusion Disposables Portfolio with NRFit™ connectorsK162219 · Smiths Medical Asd, Inc. · Jul 20, 2017
- Profoject™ LOR SyringeK261372 · CMT Health PTE., Ltd. · Sep 25, 2026
- Arrow 0.2 Micron Flat Filter, GVSK222341 · Arrow International, LLC · Feb 13, 2023
- BD Epilor SyringeK210983 · Becton, Dickinson and Company · May 19, 2022
- Plastic LOR SyringeK201356 · Jiangsu Caina Medical Co.,Ltd · Feb 12, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 7, 2011
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5140
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files