Arca
Skip to content
Tools
Tools

RayCare (2024A SP1)

System, Planning, Radiation Therapy Treatment. 510(k) K242992, from RaySearch Laboratories AB (PUBL) (Stockholm, SE). Product code MUJ, class 2.

As of Nov 20, 2026, K242992 is an FDA 510(k) held by RaySearch Laboratories AB (PUBL), substantially equivalent on Apr 17, 2025 after 203 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 203 days
  • Recalls: 2

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

RayCare is an oncology information system intended to provide information which is used to take decisions for diagnosis, treatment management, treatment planning, scheduling, treatment and follow-up of radiation therapy, medical oncology and surgical oncology.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF
  • RayCare 3.1K200487 · RaySearch Laboratories AB (PUBL) · Jun 10, 2020

Recalls

Recalls FDA ties to K242992, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
May 20, 2026Z-2646-2026, Z-2647-2026Beam set delivery note issues in which there is potential data loss if the beam set delivery note is modified simultaneously and/or if a note is updated during a treatment session, the user is not notified of the change.Open

Other MUJ clearances

The newest 510(k)s for the same product code; their median review was 237 days; see every MUJ device

Record

Type
Traditional
Received
Sep 26, 2024
Review panel
Radiology
Regulation
21 CFR 892.5050

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files