Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 510(k) K223828, from Corentec Co., Ltd. (Cheonan-Si, KR). Product code LZO, class 2.
As of Nov 19, 2026, K223828 is an FDA 510(k) held by Corentec Co., Ltd., substantially equivalent on Mar 16, 2023 after 85 days, with no recalls tied to it in FDA's recall database.
- Review time: 85 days
- Recalls: 0
BENCOX Delta Option Heads of BENCOX Total Hip System is intended for Cementless use in total or partial hip arthroplasty in primary or revision surgery for the following conditions: a. Non-inflammatory degenerative joint disease, such as avascular necrosis, osteoarthritis, traumatic arthritis b. Inflammatory degenerative joint disease, such as rheumatoid arthritis c.
- BIOLOX Delta Ceramic Femoral Heads, BIOLOX Option Ceramic Femoral Head SystemK192416 · Zimmer GmbH · Oct 1, 2019
- Bencox Foret & Bencox DeltaK121665 · Corentec Co., Ltd. · Sep 25, 2012
- BIOLOX delta Option and Extra-long HeadsK173776 · Microport Orthopedics, Inc. · Jul 6, 2018
- Exactech Bioloxdelta / Biolox Femoral Heads, 28MM Od, 32MM Od, 36MM Od, Exactech Biolox Option Adapters/Femoral HeadsK103012 · Exactech, Inc. · Nov 10, 2010
- Biolox delta Ceramic Heads, Biolox delta Option Ceramic HeadsK192683 · Biomet UK, Ltd. · Feb 27, 2020
- NEXUS® Hip StemK262473 · Microport Orthopedics, Inc. · Oct 1, 2026
- M-Vizion Femoral Revision System ExtensionK260173 · Medacta International S.A. · Sep 17, 2026
- Momentum Acetabular Cup SystemK253948 · United Orthopedic Corporation · Sep 2, 2026
- MobileLink Acetabular Cup System – 40mm ID Inserts (various)K261009 · Waldemar Link GmbH & Co. KG · Jul 6, 2026
- Z1 Hip SystemK260831 · Zimmer, Inc. · Jun 16, 2026
- Avenir® Müller Stem; Avenir Complete™ Hip SystemK260182 · Zimmer, Inc. · Apr 27, 2026
- implantcast Packaging System UpdateK260037 · Implantcast GmbH · Mar 30, 2026
- implaFit® short stemsK252401 · Implantcast GmbH · Mar 12, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 21, 2022
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3353
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files