Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented. 510(k) K260182, from Zimmer, Inc. (Warsaw, IN). Product code LZO, class 2.
As of Nov 19, 2026, K260182 is an FDA 510(k) held by Zimmer, Inc., substantially equivalent on Apr 27, 2026 after 96 days, with no recalls tied to it in FDA's recall database.
- Review time: 96 days
- Recalls: 0
The Avenir Müller Uncemented Hip Stems are intended for cementless use in total or hemi hip arthroplasty and are indicated for the following conditions: • Noninflammatory degenerative joint disease (NIDJD), e.g. avascular necrosis, osteoarthritis, and inflammatory joint disease (IJD), e.g. rheumatoid arthritis. • Acute traumatic fracture of the femoral head or neck.
- Avenir Muller Stem, Avenir Cemented Hip StemK193030 · Zimmer GmbH · Dec 6, 2019
- Avenir Complete Hip SystemK182048 · Zimmer, Inc. · Dec 7, 2018
- Avenir Complete Hip System, Size 0 Coxa VaraK192189 · Zimmer, Inc. · Dec 18, 2019
- NEXUS® Hip StemK262473 · Microport Orthopedics, Inc. · Oct 1, 2026
- M-Vizion Femoral Revision System ExtensionK260173 · Medacta International S.A. · Sep 17, 2026
- Momentum Acetabular Cup SystemK253948 · United Orthopedic Corporation · Sep 2, 2026
- MobileLink Acetabular Cup System – 40mm ID Inserts (various)K261009 · Waldemar Link GmbH & Co. KG · Jul 6, 2026
- Z1 Hip SystemK260831 · Zimmer, Inc. · Jun 16, 2026
- implantcast Packaging System UpdateK260037 · Implantcast GmbH · Mar 30, 2026
- implaFit® short stemsK252401 · Implantcast GmbH · Mar 12, 2026
- Libertas Taper Short (TS) Uncemented Femoral Stem (Libertas TS Stem)K253171 · Maxx Orthopedics, Inc. · Jan 15, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 21, 2026
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3353
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files