GEHC DXA Bone Densitometers with enCORE version 18
Densitometer, Bone. 510(k) K191112, from GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC (Madison, WI). Product code KGI, class 2.
As of Nov 21, 2026, K191112 is an FDA 510(k) held by GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, substantially equivalent on Sep 19, 2019 after 146 days, with 1 recall tied to it in FDA's recall database.
- Review time: 146 days
- Recalls: 1
- Cited as a predicate by: 2 devices
A) Provides an estimate of bone mineral density at various anatomical sites (Spine, Femur, Total Body, and Forearm). These values can then be compared to an adult reference population at the sole discretion of the physician.
- GE Lunar DXA Bone Densitometers with enCORE version 17K161682 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Dec 2, 2016
- TBS iNsightK152299 · Medimaps Group SA · Apr 29, 2016
- GE Lunar Body Composition SoftwareK071570 · Ge Medical Systems Lunar · Jun 27, 2007
- Lunar AstraK252718 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Apr 20, 2026
- 3D-ShaperK251022 · 3D-Shaper Medical S.L · Sep 5, 2025
| Started | Recall | Status |
|---|---|---|
| Dec 3, 2019 | Z-1712-2020An issue with the Lunar iDXA control panel may cause the start button to not release and potentially contribute to an accidental radiation occurrence. | Open |
- BoneVueK254072 · Curvebeam AI / Curvebeam, LLC · Sep 11, 2026
- Lunar AstraK252718 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Apr 20, 2026
- 3D-ShaperK251022 · 3D-Shaper Medical S.L · Sep 5, 2025
- BunkerHill BMDK242295 · BunkerHill Health · Apr 8, 2025
- TBS iNsight (V4)K243218 · Medimaps Group SA · Jan 17, 2025
- VirtuOstK220402 · O.N. Diagnostics · May 19, 2023
- 3D-ShaperK220822 · 3D-Shaper Medical S.L · Dec 9, 2022
- ABMD SoftwareK213760 · HeartLung Corporation · Jul 29, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 26, 2019
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1170
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files