TBS iNsight
Densitometer, Bone. 510(k) K152299, from Medimaps Group SA (Plan Les Ouates, CH). Product code KGI, class 2.
As of Nov 21, 2026, K152299 is an FDA 510(k) held by Medimaps Group SA, substantially equivalent on Apr 29, 2016 after 260 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 260 days
- Recalls: 2
- Cited as a predicate by: 3 devices
TBS iNsight is a software provided for use as a complement to both DXA analysis and clinical examination. It computes the antero-posterior spine DXA examination file and calculates a score (Trabecular Bone Score - TBS) that is compared to those of the age-matched controls. The TBS is derived from the texture of the DXA image and has been shown to be related to bone microarchitecture.
- Tbs InsightK121716 · Medimaps Group SA · Oct 5, 2012
- GE Lunar Frax 10-Year Fracture Risk Software OptionK082317 · General Electric Co. · Sep 26, 2008
- Lunar AstraK252718 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Apr 20, 2026
- TBS iNsight (V4)K243218 · Medimaps Group SA · Jan 17, 2025
- GEHC DXA Bone Densitometers with enCORE version 18K191112 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Sep 19, 2019
| Feb 3, 2025 | Z-1250-2025Potential variability in calculations from fast array scans compared to array scans when operating on Hologic Horizon machines. | Open |
| Oct 3, 2016 | Z-0369-2017The FRAX adjusted for TBS values are not correct when: The FRAX feature is activated in TBS iNsight; and TBS has been computed from a spine scan where some vertebrae were excluded. | Terminated |
- BoneVueK254072 · Curvebeam AI / Curvebeam, LLC · Sep 11, 2026
- Lunar AstraK252718 · GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC · Apr 20, 2026
- 3D-ShaperK251022 · 3D-Shaper Medical S.L · Sep 5, 2025
- BunkerHill BMDK242295 · BunkerHill Health · Apr 8, 2025
- TBS iNsight (V4)K243218 · Medimaps Group SA · Jan 17, 2025
- VirtuOstK220402 · O.N. Diagnostics · May 19, 2023
- 3D-ShaperK220822 · 3D-Shaper Medical S.L · Dec 9, 2022
- ABMD SoftwareK213760 · HeartLung Corporation · Jul 29, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 13, 2015
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1170
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files