DxA 5000, DxI 800 Access Immunoassay System, Access Ferritin, Access Folate, Access TSH (3rd IS), Access Vitamin B12
Radioassay, Vitamin B12. 510(k) K190298, from Beckman Coulter Biomedical GmbH (Munich, DE). Product code CDD, class 2.
As of Nov 17, 2026, K190298 is an FDA 510(k) held by Beckman Coulter Biomedical GmbH, substantially equivalent on Oct 4, 2019 after 235 days, with 4 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 4, 2019
- Review time: 235 days
- Recalls: 4
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe DxA 5000 is a high-speed, modular, automated sample handling system that performs pre-analytical and post- analytical sample processing and storage. The automation system also sorts, routes, and presents sample tubes to analyzers for analysis. The DxA 5000 also consolidates a variety of analytical instruments, such as an Immunoassay analyzer, into a unified workstation on a track system.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Power Processor Sample Processing System With Generic ConnectionsK110413 · Beckman Coulter, Inc. · May 11, 2011
- Unicel Dxi 800 Access Immunoassay System, Model 973100K023764 · Beckman Coulter, Inc. · Jan 28, 2003
- Access Ferritin AssayK926221 · Bio-Rad Laboratories, Inc. · Jan 13, 1993
- Folate On The Access Immunoassay Systems, Model A14208K060774 · Beckman Coulter, Inc. · Apr 21, 2006
- Modification To Access Hypersensitive Htsh AssayK042281 · Beckman Coulter, Inc. · Sep 16, 2004
Recalls
Recalls FDA ties to K190298, newest first; each opens FDA's recall record| Jun 2, 2023 | Z-2145-2023A software defect in the DxA Automation System may cause tests to be run on patient samples in tube types not compatible with the requested test, leading to erroneous patient results | Open, Classified |
| Jun 2, 2023 | Z-2144-2023A software defect in the DxA Automation System may cause tests to be run on patient samples in tube types not compatible with the requested test, leading to erroneous patient results | Open, Classified |
| Jul 21, 2021 | Z-2602-2021There is a potential that sample carriers (w or w/o samples) within automated sampling system may transport samples to the outer lane which does not contain a physical barrier to restrain samples. Samples are dropped… | Terminated |
| Jun 17, 2020 | Z-2983-2020The DxA 5000 instructions for use may be confusing regarding the re-use of sample IDs. Beckman Coulter has received complaints where the re-use of sample barcodes were not being detected by the system . | Terminated |
Other CDD Clearances
The newest 510(k)s for the same product code; see every CDD device- ARCHITECT Active-B12 (Holotranscobalamin)K233541 · Axis-Shield Diagnostics, Ltd. · Jul 31, 2024
- Access Vitamin B12K223289 · Beckman Coulter, Inc. · Dec 23, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 11, 2019
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1810
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files