Catheter, Continuous Flush. 510(k) K163701, from Boston Scientific Corporation (Maple Grove, MN). Product code KRA, class 2.

As of Nov 21, 2026, K163701 is an FDA 510(k) held by Boston Scientific Corporation, substantially equivalent on May 16, 2017 after 138 days, with 25 recalls tied to it in FDA's recall database.

  • Review time: 138 days
  • Recalls: 25+
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Direxion and Direxion HI-FLO Torqueable Microcatheters are intended for peripheral vascular use. The pre-loaded Fathom and Transend Guidewires can be used to selectively introduce and position the microcatheter in the peripheral vasculature. The microcatheter can be used for controlled and selective infusion of diagnostic, embolic, or therapeutic materials into the vessel.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K163701, newest first; the 25 newest; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Sep 16, 2026Z-0262-2027, Z-0224-2027, Z-0234-2027, Z-0249-2027, Z-0232-2027, Z-0255-2027, Z-0254-2027, Z-0227-2027, Z-0230-2027, Z-0245-2027, Z-0252-2027, Z-0258-2027, Z-0259-2027, Z-0246-2027, Z-0231-2027, Z-0253-2027, Z-0261-2027, Z-0247-2027, Z-0225-2027, Z-0250-2027, Z-0237-2027, Z-0229-2027, Z-0242-2027, Z-0238-2027, Z-0260-2027The product is defective due to insufficient UV curing of the hydrophilic coating which is present on the outer surface of the distal segment of the microcatheters and raised ridges on nitinol sleeves due to laser…Open

Other KRA clearances

The newest 510(k)s for the same product code; their median review was 257 days; see every KRA device

Record

Type
Special
Received
Dec 29, 2016
Review panel
Cardiovascular
Regulation
21 CFR 870.1210

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.