KRA: Catheter, Continuous Flush
FDA product code KRA. Class II, classified under 21 CFR 870.1210. What the classification flags say about Part 820 under the QMSR.
As of Nov 2, 2026, FDA product code KRA (Catheter, Continuous Flush) is Class II under 21 CFR 870.1210, reviewed through 510(k), with 177 linked 510(k), De Novo or BK numbers, 0 PMAs and 137 recall product records.
Classification
- Product code
- KRA
- Device name
- Catheter, Continuous Flush
- Device class
- Class II
- Regulation
- 21 CFR 870.1210
- Review panel
- Cardiovascular
- Premarket route
- 510(k)
- CGMP-exempt flag
- No
- Life-sustaining flag
- No
- Implant flag
- No
- Third-party review
- Candidate for third-party review
- Summary malfunction reporting
- Eligible
Data from openFDA as of 2 November 2026. Read the record on openFDA · FDA product code classification database
Part 820 requirements the flags point to
Part 820 rules for KRA
- CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
- Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
- Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
- Rule names this classRule names Class II.21 CFR 820.10(c) requires manufacturers of class II and class III devices to comply with clause 7.3 and its subclauses.21 CFR 820.10
- Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
- Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
- Complaint and record content21 CFR 820.35
- Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions
These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.
Clearances and recalls on record
- 510(k), De Novo and BK numbers linked
- 177 · Search these clearances
- PMA numbers linked
- 0
- Recall product records
- 137
- Adverse event reports
- Search MAUDE for KRA
Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.
Newest KRA clearances
- TriSalus TriNav Advance Infusion System: Trisalus Life Sciences, Sep 21, 2026
- Extroducer Infusion Catheter System: SmartWise Sweden AB, Sep 11, 2026
- Verge Microcatheter: Instylla, Inc., Jun 11, 2026
- TruSelect 2.6 Microcatheter: Boston Scientific Corporation, May 15, 2026
- InVera Infusion Device: Invera Medical, Mar 12, 2026
- Micro Catheter: Suzhou Zenith Vascular SciTech Limited, Jul 30, 2025
- XO Cath Microcatheter (E20-090-S, E20-110-S, E20-130-S, E20-150-S, E20-175-S…: Transit Scientific, LLC, Nov 29, 2023
- Peregrine System Infusion Catheter 4-7 mm, Peregrine System Infusion Catheter…: Ablative Solutions, Inc., Jul 5, 2023
- ScleroSafe 150 mm, ScleroSafe 350 mm: Vvt Medical , Ltd., Jun 20, 2023
- TriSalus TriNav® LV Infusion System: Trisalus Life Sciences, May 2, 2023
Search all 7,098 product codes, or read the guide to the Part 820 rules behind these flags.
Check your quality documents against Part 820