DigitalDiagnost C50
System, X-Ray, Stationary. 510(k) K163410, from Philips Healthcare (Suzhou) Co., Ltd. (Suzhou, CN). Product code KPR, class 2.
As of Nov 20, 2026, K163410 is an FDA 510(k) held by Philips Healthcare (Suzhou) Co., Ltd., substantially equivalent on Jan 4, 2017 after 30 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 30 days
- Recalls: 4
- Cited as a predicate by: 1 device
The DigitalDiagnost C50 system is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. This device is not intended for mammographic applications.
- DuradiagnostK141381 · Philips Healthcare (Suzhou) Co., Ltd. · Jun 12, 2014
- KLS Martin Cannulated Headless ScrewsK161259 · KLS Martin L.P. · Dec 19, 2016
- DigitalDiagnost C50K201725 · Philips Healthcare (Suzhou) Co., Lit. · Jul 10, 2020
| Mar 9, 2023 | Z-1382-2023, Z-1383-2023If the PM for the telescopic carriage is not performed annually as defined in the Instructions for Use (IFU), the tension force of the spring balancer inside of the telescopic carriage will unavoidably decay through… | Open |
| Feb 25, 2022 | Z-1563-2022Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of the image on the first examination due to an issue in… | Open |
| Dec 21, 2018 | Z-2498-2019During recent evaluations of the Philips DigitalDiagnost C50 system, Philips identified a missing label. This notification is intended to provide you with information regarding what the issue is, and relevant affected… | Terminated |
- EXSYS DEXi (EXSYS DEXi-S40S); EXSYS DEXi (EXSYS DEXi-S40P); EXSYS DEXi (EXSYS DEXi-S40T); EXSYS DEXi (EXSYS DEXi-S50HK260227 · DRTECH Corporation · Sep 8, 2026
- MULTIX Impact; MULTIX Impact CK260488 · Siemens Medical Solutions USA, Inc. · Aug 31, 2026
- GC85AK260481 · Samsung Electronics Co., Ltd. · Aug 27, 2026
- DRE DuoK260482 · Jpi Healthcare Co, Ltd. · Jun 15, 2026
- AeroDR TX c02K253446 · Dk Medical Systems Co., Ltd. · Apr 10, 2026
- DRX-Evolution Plus X-ray System, DRX-Compass Mobile X-ray System, Lux HD 35 detector, Lux HD 43 detectorK250954 · Carestream Health · Jan 20, 2026
- uDR Arria & uDR ArisK252000 · Shanghai United Imaging Healthcare Co., Ltd. · Nov 26, 2025
- uDR Aurora CXK251167 · Shanghai United Imaging Healthcare Co., Ltd. · Sep 19, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Dec 5, 2016
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files