NIRO-200NX DP
Oximeter, Tissue Saturation. 510(k) K162117, from Hamamatsu Photonics K.K. (Hamamatsu City, JP). Product code MUD, class 2.
As of Nov 18, 2026, K162117 is an FDA 510(k) held by Hamamatsu Photonics K.K., substantially equivalent on Oct 25, 2016 after 88 days, with no recalls tied to it in FDA's recall database.
- Review time: 88 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe NIRO-200NX DP is intended for use as an adjunct trend monitor of regional hemoglobin oxygen saturation and relative level of oxygenated hemoglobin and deoxygenated hemoglobin of blood in brain or in other tissue beneath the probes in any individual. The clinical value of trend data has not been demonstrated in disease states.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- NIRO-200NXK143219 · Hamamatsu Photonics K.K. · Jul 31, 2015
Cited as a predicate
1 later 510(k) summary names this device as a predicate- Masimo O3 Regional Oximeter SystemK201432 · Masimo Corporation · Aug 29, 2020
Other MUD clearances
The newest 510(k)s for the same product code; their median review was 151 days; see every MUD device- OxySight for MolecuLightDX+K262858 · MolecuLight, Inc. · Nov 5, 2026
- Spectrum-2K254129 · Neko Health AB · May 22, 2026
- Masimo O3 Regional OximeterK243324 · Masimo Corporation · Jul 17, 2025
- Lap.Ox™ Laparoscopic Tissue OximeterK250519 · ViOptix, Inc. · Jun 26, 2025
- Cerebral Autoregulation Index (CAI) AlgorithmK240596 · Edwards Lifesciences · Oct 16, 2024
- ODI-TechK241393 · Odi Medical AS · Aug 30, 2024
- SnapshotNIR model KD205K240601 · Kent Imaging, Inc. · Apr 2, 2024
- OxiplexTS200K232385 · Iss Medical, Inc. · Mar 1, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 29, 2016
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files