Cerebral Autoregulation Index (CAI) Algorithm
Oximeter, Tissue Saturation. 510(k) K240596, from Edwards Lifesciences (Irvine, CA). Product code MUD, class 2.
As of Nov 18, 2026, K240596 is an FDA 510(k) held by Edwards Lifesciences, substantially equivalent on Oct 16, 2024 after 226 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 16, 2024
- Review time: 226 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFCerebral Autoregulation Index (CAI) Algorithm is an informational index intended to represent a surrogate measurement of whether cerebral autoregulation is likely intact or is likely impaired as expressed by the level of coherence or lack thereof between Mean Arterial Pressure (MAP) and the Absolute Levels of Blood Oxygenation Saturation (StO2) in patient's cerebral tissue.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Cerebral Adaptive Index (CAI) AlgorithmK223651 · Edwards Lifesciences, LLC · May 26, 2023
Other MUD Clearances
The newest 510(k)s for the same product code; their median review was 151 days; see every MUD device- Spectrum-2K254129 · Neko Health AB · May 22, 2026
- Masimo O3 Regional OximeterK243324 · Masimo Corporation · Jul 17, 2025
- Lap.Ox Laparoscopic Tissue OximeterK250519 · ViOptix, Inc. · Jun 26, 2025
- ODI-TechK241393 · Odi Medical AS · Aug 30, 2024
- SnapshotNIR model KD205K240601 · Kent Imaging, Inc. · Apr 2, 2024
- OxiplexTS200K232385 · Iss Medical, Inc. · Mar 1, 2024
- Intra.Ox 2.0 Handheld Tissue OximeterK233488 · Vioptix, Inc. · Feb 28, 2024
- Edwards Algorithm for Measurement of Blood HemoglobinK230612 · Edwards Lifesciences, LLC · Nov 17, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 4, 2024
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files